性猛交XXXX乱大交派对,四虎影视WWW在线观看免费 ,137最大但人文艺术摄影,联系附近成熟妇女

深圳市鑫博恒業(yè)科技有限公司

示溫貼紙,英國(guó)測(cè)溫試紙,omega插頭,k型感溫線

化工儀器網(wǎng)收藏該商鋪

17

聯(lián)系電話

13823144468

您所在位置:
深圳市鑫博恒業(yè)科技有限公司>>美國(guó)omega壓力傳感器>> DPG1000ADA-100G-2N壓力表 美國(guó)omega
 QQ交談
產(chǎn)品展示

DPG1000ADA-100G-2N壓力表 美國(guó)omega

  • 公司名稱:
  • 更新時(shí)間:
  • 所 在 地:
  • 生產(chǎn)地址:
  • 瀏覽次數(shù):
  • 深圳市鑫博恒業(yè)科技有限公司
  • 2024-04-06 13:25:47
  • 深圳市
  • 美國(guó)omega
  • 1903

我要詢價(jià)

【簡(jiǎn)單介紹】

品牌 OMEGA/美國(guó)
DPG1000ADA-100G-2N壓力表 美國(guó)omega, 一手貨源,優(yōu)勢(shì)批發(fā),精度高,是優(yōu)質(zhì)的壓力傳感器

【詳細(xì)說明】


DPG1000ADA-100G-2N壓力表 美國(guó)omega

報(bào)警裝置和模擬輸出功能的數(shù)字壓力計(jì)
DPG1000ADA_DPG1000DAR系列
DPG1000ADA_DPG1000DAR 系列:報(bào)警裝置和模擬輸出功能的數(shù)字壓力計(jì)
DPG1000ADA-15G-1N
AD or DC Powered with Dual Alarms
DC Powered with Dual Alarms and Analog Output
Ranges between 15 psi and 3000 psi
Normal or Reverse Acting Alarms
Hi/Lo, Hi/Hi, or Lo/Lo Alarms available
Colored LED Alarm Status Indicators
Using the DPG1000ADA and DPG1000DAR Alarm Outputs Normal (Fail-safe) vs. Reverse Action—The convention for alarm action is that with the normal or fail-safe configuration, the alarm output relays will be CLOSED (relay energized) for a clear or non-alarm condition and OPEN (relay not energized) for an alarm condition. This is primarily for users who require an alarm condition if the gauge loses power or suffers a catastrophic failure. In the wiring diagrams, the normally closed and normally open designations refer to standard relay terminology (i.e., the relay contact status with the relay coil not energized). Therefore, with the normal (fail-safe) configuration in a green or non-alarm condition, the relay will be energized so that continuity can be expected between the common and normally open leads. In a red or alarm condition, the relay will be open (not energized) so that continuity can be expected between the common and normally closed leads.
Contact Rating and Protection The contacts of the alarm relays are rated at 1 A/24 Vdc or 0.5 A/ 115 Vac. Switching loads greater than the rating, or switching large inductive loads, will shorten the useful life of the contacts. In lowlevel switching or with dry contacts, the user should consider whether external contact protection, such as snubber networks or arc suppression networks, is required to protect the contacts. In addition, no internal fusing is included in the DPG1000 contact circuits. The circuit external to the gauge alarm outputs should be fused by the user in applications in which good design dictates this practice.
Using the DPG1000DAR Analog Output The analog output is easy to use if a few system considerations are observed. The DPG1000DAR is DC powered, with the gauge power supply (–) tied to the 4 to 20 mA (–). Therefore, the DC supply (–) lead should be considered common with regard to the analog output (–) or ground connection in the user’s system. Be sure to observe the output compliance (voltage drive) capabilities of the gauge. The compliance, and therefore the maximum loop resistance the output can drive, is a function of the supply voltage to the gauge. Consult the manual for maximum loop resistance vs. supply voltage. Too large a loop resistance will cause the gauge output to “l(fā)imit" or saturate before reaching its full 20 mA output.
DPG1000ADA AC/DC Powered with Dual Alarms
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C" (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bicolor (red/green) LEDs on front panel
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation
Alarm Response Time: 100 ms typical
Power: Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS)
DPG1000DAR DC Powered with Dual Alarms and 4 to 20 mA Output
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; test calibration level, 0 to 100% range; top-accessible, multiturn potentiometers analog output zero/span; internal potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C" (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bi-color (red/green) LEDs on front panel
Alarm Response Time: 100 ms typical
Analog Output: 4 to 20 mA DC; output drive (compliance) determined by power source
Analog Output Response Time: 50 ms, typical
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status and simultaneously sets display and analog output to “calibration" level, independent of pressure input, to allow testing system operation
Power: Any DC source of 9 to 32 Vdc, 1.0 W max
Electrical Connection: 0.9 m (3') long, 4-conductor 22 AWG shielded cable for power and retransmitted output; 0.9 m (3') long, 6-conductor 22 AWG cable for alarm contacts
ALARMS (final siffix 1N standard)
1 = HI/LO (standard)
2= HI/HI
3= LO/LO
N = Normal Acting (standard)
R = Reverse Acting
Example: DPG1000ANA-15G-3R HAS LO/LO ALARMS, Reverse Acting

 DPG1000ADA-100G-2N壓力表 美國(guó)omega 

相關(guān)產(chǎn)品:

DPG1000B-2KG壓力表 美國(guó)omega

    
留言框
感興趣的產(chǎn)品: *
留言內(nèi)容:
您的姓名: *
您的單位:
聯(lián)系電話: *
微信:
常用郵箱:
詳細(xì)地址:
省份: *
驗(yàn)證碼: * =   請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
      

相關(guān)產(chǎn)品

產(chǎn)品搜索

請(qǐng)輸入產(chǎn)品關(guān)鍵字:

聯(lián)系方式
地址:深圳市福田區(qū)華強(qiáng)北路華強(qiáng)廣場(chǎng)A棟17A(華強(qiáng)北地鐵站-A口)
郵編:518031
聯(lián)系人:趙先華
電話:0755-82768776,82736276
傳真:0755-83041664
手機(jī):13823144468
留言:發(fā)送留言
個(gè)性化:www.xbtes.com
網(wǎng)址:www.xb5j.com
商鋪:http://www.syzwkj.com/st98310/
| 商鋪首頁(yè) | 公司檔案 | 產(chǎn)品展示 | 供應(yīng)信息 | 公司動(dòng)態(tài) | 詢價(jià)留言 | 聯(lián)系我們 | 會(huì)員管理 |
化工儀器網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究.Copyright(C) http://www.syzwkj.com, All rights reserved.
以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。
二維碼 在線交流

掃一掃訪問手機(jī)站
禹城市| 开平市| 会理县| 皋兰县| 鄄城县| 内乡县| 五常市| 时尚| 华池县| 马龙县| 绥江县| 高州市| 鹰潭市| 鞍山市| 梁河县| 潜山县| 额尔古纳市| 长治市| 弥渡县| 大厂| 大洼县| 潜江市| 景谷| 林口县| 含山县| 壤塘县| 阜康市| 辽中县| 当涂县| 临朐县| 花垣县| 定西市| 禄丰县| 营山县| 郴州市| 安陆市| 上犹县| 开化县| 格尔木市| 景洪市| 舟山市|