聯(lián)系電話
北京祥生興業(yè)科技有限公司
參考價(jià): | 面議 |
- 57000 產(chǎn)品型號(hào)
- CHROMSYSTEMS 品牌
- 代理商 廠商性質(zhì)
- 所在地
訪問(wèn)次數(shù):65更新時(shí)間:2024-09-19 08:57:44
- 聯(lián)系人:
- 張先生
- 電話:
- 13681184382
- 手機(jī):
- 13681184382
- 地址:
- 北京市北京經(jīng)濟(jì)技術(shù)開(kāi)發(fā)區(qū)同濟(jì)中路甲7號(hào)18幢A座1010
- 個(gè)性化:
- www.xiangshengbio.com
掃一掃訪問(wèn)手機(jī)商鋪
溫馨提示:僅用于科研,不可用于臨床治療
- 供應(yīng)商:
祥生興業(yè)
- 規(guī)格:
960 analyses
- 新生兒遺傳代謝疾病檢測(cè),串聯(lián)質(zhì)譜分析方法試劑盒LC-MS/MS 非衍生化
-
All required and isotope labelled standards included
-
Dried blood spot controls included
-
Direct sample injection without derivatisation
-
High selectivity and sensitivity by MS/MS detection
- Punch 3 mm dried blood spot disk out of the filter card into a well plate.
- Add 100 µl Internal Standard, agitate for 20 min.
- Inject 10 µl of the extract into the LC-MS/MS system.
This Chromsystems reagent kit allows the very fast and reliable determination of amino acids and acylcarnitines from dried blood spot samples as part of the newborn screening for amino acid and fatty acid metabolic disorders using tandem mass spectrometry. Sample preparation is based on effective extraction of the analytes from the filter card without any further sample preparation steps required. The test utilises stable isotope labelled internal standards for calibration and measurement to ensure reliable and precise quantification of the analytes. Due to the time saving sample preparation and high precision of the MRM method, this direct injection kit stands out from the derivatised method. On the other hand lower sensitivity and interferences from isobaric substances (e.g. C5DC and C6OH) in acylcarnitines analyses may occur.
Specifications
Linearity: | Amino acids: 2000-2400 µmol/l (Acyl-)carnitines: 25-200 µmol/l |
Limit of quantification: | Amino acids: 2.5-30 µmol/l (Acyl-)carnitines: 0.1-1.6 µmol/l |
Recovery: | Amino acids: 64-94 % (Acyl-)carnitines: 63-102 % |
Intra-assay: | Amino acids: 2-11 % (Acyl-)carnitines: 3-12 % |
Inter-assay: | Amino acids: 3.5-18 % (Acyl-)carnitines: 4.8-14 % |
Analysis time: | < 2 min |
Cutoff thresholds
Amino acids: | ca. 30 to 1000 µmol/l |
free carnitine: | ca. 55 µmol/l |
Acylcarnitines: | ca. 0.2 to 10 µmol/l |
LC-MS/MS parameters
LC-MS/MS system. No HPLC column is required.
Injection volume: | 10 µl |
Flow gradient: | 20 to 600 µl/min |
Autosampler rinsing solution: | Rinsing Solution (57007) |
MS/MS Mode: | MRM |
Mass transitions: | |
Alanine | 90 > 44 |
Alanine-D4 | 94 > 48 |
Arginine | 175 > 70 |
Arginine-D7 | 182 > 77 |
Aspartic acid | 134 > 116 |
Aspartic acid-D3 | 137 > 119 |
Citrulline | 176 > 113 |
Citrulline-D2 | 178 > 115 |
Glutamic acid | 148 > 130 |
Glutamic acid-D5 | 153 > 135 |
Glycine | 76 > 30 |
Glycine-13C2-15N | 79 > 32 |
Leucine | 132 > 86 |
Leucine-D3 | 135 > 89 |
Methionine | 150 > 133 |
Methionine-D3 | 153 > 136 |
Ornithine | 133 > 70 |
Ornithine-D6 | 139 > 76 |
Phenylalanine | 166 > 120 |
Phenylanlanine-D5 | 171 > 125 |
Proline | 116 > 70 |
Proline-D7 | 123 > 77 |
Tyrosine | 182 > 136 |
Tyrosine-D4 | 186 > 140 |
Valine | 118 > 72 |
Valine-D8 | 126 > 80 |
Free carnitine | 162 >85 |
Carnitine-D9 | 171 > 85 |
C2-Carnitine | 204 > 85 |
C2-Carnitine-D3 | 207 > 85 |
C3-Carnitine | 218 > 85 |
C3-Carnitine-D3 | 221 > 85 |
C4-Carnitine | 232 > 85 |
C4-Carnitine-D3 | 235 > 85 |
C5-Carnitine | 246 > 85 |
C5-Carnitine-D9 | 255 > 85 |
C5DC-Carnitine | 276 > 85 |
C5DC-Carnitine-D6 | 282 > 85 |
C6-Carnitine | 260 > 85 |
C6-Carnitine-D3 | 263 > 85 |
C8-Carnitine | 288 > 85 |
C8-Carnitine-D3 | 291 > 85 |
C10-Carnitine | 316 > 85 |
C10-Carnitine-D3 | 319 > 85 |
C12-Carnitine | 344 > 85 |
C12-Carnitine-D3 | 347 > 85 |
C14-Carnitine | 372 > 85 |
C14-Carnitine-D3 | 375 > 85 |
C16-Carnitine | 400 > 85 |
C16-Carnitine-D3 | 403 > 85 |
C18-Carnitine | 428 > 85 |
C18-Carnitine-D3 | 431 > 85 |
Sample preparation
Order no. | Product |
---|---|
57000 | MassChrom® Reagent kit for the determination of amino acids and acylcarnitines from dried blood spot (LC-MS/MS)/Non Derivatised with regular 96 well plates. For 960 analyses. |
57000/F | MassChrom® Reagent kit for the determination of amino acids and acylcarnitines from dried blood spot (LC-MS/MS)/Non Derivatised with 96 well filter plates. For 960 analyses. |
Separately available components | |
57001 | Mobile Phase, 1000 ml |
57002 | Mobile Phase, 10 x 1000 ml |
57004/T | Internal Standard (lyoph.), 25 ml |
57004 | Internal Standard (lyoph.), 4 x 25 ml |
57007 | Rinsing Solution, 1000 ml |
57008 | Extraction Buffer, 100 ml |
57010 | 96-Well-Plates, V-Boden, 5 pcs. |
55011 | Protective sheets for 96 well plates, 10 pcs. |
57057 | 96 Well filter plates, 5 pcs. |
55013 | Piercable adhesive seal for 96 well plates, 10 pcs. |
Startup accessories | |
55015 | Restrictor Capillary, 1 pc. |
55016 | Adapter collar for centrifugation, 2 pcs. |
57099 | Tuning Mix, incl. all analytes, 2 ml |
55033 | PEEK prefilter, 5 µm, 5 pcs. |
15010 | PEEK prefilter housing, 1 pc. |
Chromsystems quality control material (filter spot) | |
0191 | MassCheck® Amino Acids, Acylcarnitines Dried Blood Spot Control, Bi-Level (I+II), 2 x 3 Spots |
0192 | MassCheck® Amino Acids, Acylcarnitines Dried Blood Spot Control, Level I, 1 x 3 spots |
0193 | MassCheck® Amino Acids, Acylcarnitines Dried Blood Spot Control, Level II, 1 x 3 spots |