供貨周期 現(xiàn)貨 規(guī)格 CRD 180 (0.4 mm)
貨號 079960 應(yīng)用領(lǐng)域 醫(yī)療衛(wèi)生,環(huán)保,食品,化工,石油
Dionex CRD碳酸鹽去除裝置
從抑制洗脫液流通過擴散通過碳酸酯的選擇性透氣膜的壁除去二氧化碳。

Dionex CRD碳酸鹽去除裝置

 

Thermo Scientific的戴安™酸鹽去除裝置(CRD 180,200和300)從抑制洗脫液流通過擴散通過碳酸酯的選擇性透氣膜的壁除去二氧化碳。與碳酸洗脫液系統(tǒng)的戴安CRD 300降低了背景信號,以幾乎相同的水平作為氫氧化物洗脫液。抑制器后鉛垂,二氧化碳傳輸是由堿性溶液的逆流輔助。

戴安CRD 180和200用于從氫氧化物洗脫液系統(tǒng)中除去碳酸優(yōu)化
盡量減少使用戴安CRD 180或200可以提高量化碳酸鹽
戴安CRD 180的減小的膜長度為根據(jù)4微米樹脂柱優(yōu)化
戴安CRD 300的增加的膜長度為碳酸鹽淋洗液系統(tǒng)進行了優(yōu)化
減少與戴安CRD 300結(jié)果基線為碳酸鹽淋洗液系統(tǒng)更高的靈敏度
與一戴安CRD 300碳酸背景消除增加了線性范圍

 

 

Dionex CRD碳酸鹽去除裝置

訂貨信息:

CRD 180   (0.4 mm)                                  079960     
CRD 200 (4 mm)     062983
CRD 200 (2 mm)     062986
CRD 200 (0.4 mm)     072054
CRD 300 (4 mm)     064637
CRD 300 (2 mm)     064638
CRD 300 (4 mm) with Peristaltic Pump Kit     064905
CRD 300 (2 mm) with Peristaltic Pump Kit     064906
Santoprene Tubing for Peristaltic Pump     068518
Ship Kit for Peristaltic Pump/CRD 300     064911
CRD 300 (4 mm) with VP Vacuum Pump Kit     068475
CRD 300 (2 mm) with VP Vacuum Pump Kit     068474

 

Reduces Carbonate for Improved Sensitivity

The Thermo Scientific Dionex Carbonate Removal Device (CRD 180, 200 and 300) remove carbon dioxide from the suppressed eluent stream by diffusion through the walls of a carbonate selective gas permeable membrane. With carbonate eluent systems the Dionex CRD 300 reduces the background signal to nearly the same levels as that of hydroxide eluents. Plumbed after the suppressor, the carbon dioxide transfer is aided by a countercurrent flow of basic solution.

  • The Dionex CRD 180 and 200 are optimized for the removal of carbonate from hydroxide eluent systems

  • Minimizing carbonate using the Dionex CRD 180 or 200 can improve quantification

  • The reduced membrane length of the Dionex CRD 180 is optimized for columns based on 4 μm resins

  • The increased membrane length of the Dionex CRD 300 is optimized for carbonate eluent systems

  • Reducing the baseline with a Dionex CRD 300 results in higher sensitivity for carbonate eluent systems

  • Elimination of the carbonic acid background with a Dionex CRD 300 increases the linearity range

Dionex CRD 200 Carbonate Removal Device

Exposure to carbon dioxide can cause samples to become contaminated with carbonate. High levels of carbonate originating from dissolved carbon dioxide can interfere with the accurate determination of analytes of interest, such as sulfate and nitrite. The Dionex CRD 200 is a device used to remove the carbonate peak contributed by the sample.

The Dionex CRD 200 can be installed easily in any Thermo Scientific Dionex IC system equipped with an eluent generator, Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column, and Thermo Scientific Dionex AERS 500 Anion Electrolytically Regenerated Suppressor or Thermo Scientific Dionex ACES 300 Anion Capillary Electrolytic Suppressor, and requires no reagents or software control. The Dionex CRD 200 is a low-dispersion devices designed specifically for use with hydroxide- and borate-based chemistries using Thermo Scientific Dionex columns.

The Dionex CRD 200 is available in three formats. The Dionex CRD 200 (4 mm) supports carbonate removal from standard bore systems, while the Dionex CRD 200 (2 mm) supports carbonate removal from microbore systems; the Dionex CRD 200 (0.4 mm) supports carbonate removal from capillary-scale systems at flow rates of 5 – 30 μL/min.

 

A significant amount of carbonate is removed using the Dionex CRD 200 Carbonate Removal Device.

Dionex CRD 300 Carbonate Removal Device

Carbonate eluents are suppressed to relatively low-conductivity carbonate acid, but the residual conductivity of the carbonic acid has several undesirable effects. Carbonic acid can mask small peaks, decreasing the limit of detection (LOD) during trace analyses. In a background of carbonic acid, the linear range of most species is limited, and the residual background conductivity creates a large void dip which can hamper the integration of early eluting species. The CRD 300 is a device used to remove the carbonic acid from the suppressed eluent, providing hydroxide-like detection to systems using carbonate eluents.

The Dionex CRD 300 can be installed easily in any Dionex IC system running carbonate as an eluent with a Dionex AERS 500 suppressor. The Dionex CRD 300 requires either a constant flow of basic solution from a peristaltic pump or evacuation by a vacuum pump. The Dionex CRD 300 is designed specifically for use with carbonate eluent based chemistries using Dionex columns.

The Dionex CRD 300 is available in two formats. The Dionex CRD 300 (4 mm) supports carbonate removal from standard bore systems, while the Dionex CRD 300 (2 mm) supports carbonate removal from microbore systems.

 

Background signal is reduced using the Dionex CRD 300 Carbonate Removal Device.

Dionex CRD 180 Carbonate Removal Device

The Dionex CRD 180 is a version of the Dionex CRD 200 that has reduced internal volume. This facilitates operation in conjunction with 4 μm resin packed capillary columns without unacceptable loss of peak efficiency. However the Dionex CRD 180 has less capacity for the removal of carbonate than the Dionex CRD 200, and is therefore not recommended for use with columns packed with resin larger than 4 μm.

The Dionex CRD 180 can be installed easily in a Dionex Capillary IC system equipped with an eluent generator, Dionex CR-ATC Continuously Regenerated Anion Trap Column, and Dionex ACES 300 suppressor. The Dionex CRD 180 requires no reagents or software control. The Dionex CRD 180 is an ultra-low-dispersion device designed specifically for use with hydroxide-based chemistries using Dionex columns.

The Dionex CRD 180 is only available in capillary (0.4 mm) format for use with 0.25 mm and 0.4 mm capillary columns. Microbore and standard-bore systems using 4 μm resin packed columns should use the Dionex CRD 200.

Dionex Carbonate Removal Device CRD 180 Specifications
Hardware Dimensions
( h × w × d)
11.3 cm × 9.3 cm × 2.1cm
(4.5 in. × 3.7 in. × 0.8 in.)
Void Volume0.4 mm: ~1 μL

 

Dionex Carbonate Removal Device CRD 200 Specifications
Hardware Dimensions
( h × w × d) (4 mm and 2 mm)
2.0 cm × 4.4 cm × 7cm
(0.8 in. × 1.7 in. × 2.8 in.)
Hardware Dimensions
( h × w × d) (0.4 mm)
11.3 cm × 9.3 cm × 2.1cm
(4.5 in. × 3.7 in. × 0.8 in.)
Void Volume2 mm: ~40 μL
4 mm: ~200 μL
0.4 mm: ~2 μL

 

Dionex Carbonate Removal Device CRD 300 Specifications
Hardware Dimensions
( h × w × d)
2.0 cm × 4.4 cm × 7cm
(0.8 in. × 1.7 in. × 2.8 in.)
Void Volume2 mm: 80 μL
4 mm: 225 μL

 

 

Dionex CRD碳酸鹽去除

Dionex CRD碳酸鹽去除裝置$r$n從抑制洗

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,化工儀器網(wǎng)對此不承擔任何保證責任。

溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

撥打電話
在線留言
韶关市| 广水市| 安义县| 南溪县| 房产| 行唐县| 黄骅市| 潜江市| 于都县| 鄂伦春自治旗| 铅山县| 九龙县| 彭泽县| 库伦旗| 彩票| 红河县| 多伦县| 望奎县| 织金县| 汾阳市| 蚌埠市| 台州市| 崇州市| 登封市| 贵港市| 蛟河市| 六枝特区| 饶阳县| 二手房| 绥芬河市| 华坪县| 来宾市| 广德县| 谢通门县| 榕江县| 平潭县| 舒城县| 西乌珠穆沁旗| 嘉荫县| 林周县| 南丹县|