聯(lián)系電話
北京祥生興業(yè)科技有限公司
參考價(jià): | 面議 |
- 0081 產(chǎn)品型號(hào)
- CHROMSYSTEMS 品牌
- 代理商 廠商性質(zhì)
- 所在地
訪問(wèn)次數(shù):47更新時(shí)間:2024-09-19 08:51:15
- 聯(lián)系人:
- 張先生
- 電話:
- 13681184382
- 手機(jī):
- 13681184382
- 地址:
- 北京市北京經(jīng)濟(jì)技術(shù)開(kāi)發(fā)區(qū)同濟(jì)中路甲7號(hào)18幢A座1010
- 個(gè)性化:
- www.xiangshengbio.com
掃一掃訪問(wèn)手機(jī)商鋪
溫馨提示:僅用于科研,不可用于臨床治療
- 英文名:
MassCheck® Immunosuppressants Whole Blood Control (lyoph.), Four-Level (I+II+III+IV), 4 x 2 x 2 ml
- 供應(yīng)商:
祥生興業(yè)
- 保存條件:
低溫
- 規(guī)格:
4 x 2 x 2 ml
MassCheck® Immunosuppressants Whole Blood Controls
Cyclosporin A, Everolimus, Sirolimus, Tacrolimus分析物:A,依維莫司,,
Concentrations (example)
Please note: All concentrations shown here are exemplatory. They do not reflect real data for the described products. Actual concentrations depend on the production lot of each product and can exclusively be found in the product information leaflet. Please ask for these product information leaflets or download them from the service site of the Chromsystems website.
Chromsystems Immunosuppressants Control: | Level I | Level II | Level III | Level IV | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Substance | Method | Unit | Value | Range | Value | Range | Value | Range | Value | Range |
Ciclosporin A | HPLC-UV | μg/l | 96 | 77-115 | 242 | 193-290 | 476 | 381-572 | 1899 | 1519-2278 |
Dade-Behring EMIT | μg/l | 101 | 81-121 | 247 | 198-296 | 467 | 374-560 | 2051 | 1641-2461 | |
Abbott TDx | μg/l | 110 | 83-138 | 274 | 198-296 | 528 | 396-659 | 1833 | 1375-2291 | |
Rapamycin (Sirolimus) | LC-MS/MS | μg/l | 3.7 | 2.6-4.8 | 9.1 | 7.3-10.9 | 18.0 | 14.4-21.6 | 39.2 | 31.4-47.0 |
Tacrolimus (FK 506) | Abbott IMx | μg/l | 6.4 | 5.1-7.7 | 12.2 | 9.8-14.6 | 23.7 | 19.0-28.4 | 44.6 | 35.7-53.5 |
LC-MS/MS | μg/l | 3.4 | 2.7-4.1 | 8.2 | 6.6-9.8 | 18.1 | 14.5-21.7 | 36.0 | 28.8-43.2 | |
Everolimus | LC-MS/MS | μg/l | 2.5 | 1.6-3.3 | 4.4 | 2.9-6.0 | 8.9 | 5.7-11.9 | 30.1 | 21.1-39.1 |
Instructions
These Chromsystems whole blood controls are designed to monitor the accuracy and precision of analytical procedures for the quantitative determination of Ciclosporin A, Rapamycin, Tacrolimus and Everolimus in whole blood. The lyophilised control is based on human whole blood and should be used routinely according to the instructions accompanying the assay procedure being used. While following these instructions the control is to be handled in the same manner as a patient specimen.
Reconstitution
Remove the metal seal and rubber stopper from the vial. Add exactly 2.0 ml of double distilled water (possibly HPLC-grade) into the vial. Replace the stopper and allow to sit for 10 to 15 minutes at room temperature. Swirl the vial to dissolve the contents until homogeneity.
Storage conditions
Stored at <-18 °C unopened whole blood controls are stable until the expiry date which is stated on the vial labels. The reconstituted control can be stored up to one week light protected, tightly capped at +2 to +8 °C. If the controls cannot be analysed within this period, they should be aliquoted and stored frozen at <-18 °C (up to 6 months).
Ordering information
0081 | MassCheck® Immunosuppressants Whole Blood Control, Four-Level (I+II+III+IV) 4 x 2 x 2 ml |
0082 | MassCheck® Immunosuppressants Whole Blood Control, Level I, 5 x 2 ml |
0083 | MassCheck® Immunosuppressants Whole Blood Control, Level II, 5 x 2 ml |
0084 | MassCheck® Immunosuppressants Whole Blood Control, Level III, 5 x 2 ml |
0085 | MassCheck® Immunosuppressants Whole Blood Control, Level IV, 5 x 2 ml |
0089 | MassCheck® Immunosuppressants Whole Blood Blank Control, 5 x 2 ml |
產(chǎn)品信息 http://chromsystems.com/en-gb/produkte/therapeutisches-drug-monitoring/masstox-r-immunsuppressiva