性猛交XXXX乱大交派对,四虎影视WWW在线观看免费 ,137最大但人文艺术摄影,联系附近成熟妇女

您好, 歡迎來到化工儀器網(wǎng)

| 注冊(cè)| 產(chǎn)品展廳| 收藏該商鋪

18060909291

products

目錄:廈門地坤科技有限公司>>儀器儀表>>儀器>> GFG-809110低頻信號(hào)發(fā)生器

GFG-809110低頻信號(hào)發(fā)生器
  • GFG-809110低頻信號(hào)發(fā)生器
參考價(jià) 面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
參考價(jià) 面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 品牌 廈門地坤
  • 型號(hào)
  • 廠商性質(zhì) 生產(chǎn)商
  • 所在地 廈門市
屬性

應(yīng)用領(lǐng)域:文體,建材,電子,汽車,綜合

>

更新時(shí)間:2019-12-24 15:53:04瀏覽次數(shù):1171評(píng)價(jià)

聯(lián)系我們時(shí)請(qǐng)說明是化工儀器網(wǎng)上看到的信息,謝謝!

同類優(yōu)質(zhì)產(chǎn)品

更多產(chǎn)品
應(yīng)用領(lǐng)域 文體,建材,電子,汽車,綜合
GFG-809110低頻信號(hào)發(fā)生器More than 5Vrms at no load and more than 2.8Vrms on 600Ω loading (sine wave). Output level can be adjusted by a 10dB-step, 6 range attenuator and a level adjuster.

GFG-809110低頻信號(hào)發(fā)生器

1.FEATURES

   Reliable circuitry insure high stability and accuracy

   Easy operation on vertical type panel assembling

   Frequency range from 10Hz to 1MHz selectable in 5 ranges are       calibrated with single-scale graduations.

   More than 5Vrms at no load and more than 2.8Vrms on 600Ω loading (sine wave). Output level can be adjusted by a 10dB-step, 6 range attenuator and a level adjuster.

   Sine wave and square waves is available.

   Synchronizing input terminal

 

2.Specifications

   Frequency range:

   X1 range:   10Hz-100Hz

   X10 range:  100Hz-1KHz

   X100range:  1KHz-10KHz

   X1K range:  10KHZ-100KHz

   X10K range:  100KHz-1MHz

   Sine wave characteristics

   Output volGFG-809110: 5V rms or more

   Output distortion: 400Hz-20KHz, 0.1% or less

                   (X100 range for 1KHz)

                  50Hz-500KHz 0.5% or less

   Output Flatness: ±1.5 dB (refer to 1KHz)

   Square wave characteristics:

   Output volGFG-809110: 10Vp.p or more

   Rise time: 0.25 us or less

   Duty  ratio: 50%±5%  (refer to 1KHz)

   External synchronization characteristics

   Range±3% of oscillator frequency

   Input impedance: 10K approximate

   Maxi mun input: 10V rms

   Output characteristics:

   Impedance: 600Ω±10%

   Attenuator: 0dB, -10dB, -20dB, -30dB, -40dB, and -50dB in 6 steps (accuracy +1 dB at 600Ω load)

   Power requirement:

   Input: AC 110V or 220V, 50/60Hz

   Consumption: 5 Watt

   Dimension:

   142(w)*233(D)*197(H) mm

   Weight:3.5Kg

   Accessories:

   Power cord           1pc

   Test clip              1pc

   Instruction manual       1pc

 

3.CIRCUIT DESCRIPTION

1) Summary

   When reading the following descriptions, refer to the block diagram(Fig.1) and the schematic diagram.

   The sine-wave signal generated by the oscillator is fed through the WAVE FROM selector switch set at the “ ” position to the OUTPUT control, to adjust on any desired volGFG-809110.

   If the WAVE FORM switch is in the “” position, square wave is fed to the OUTPUT control to adjust on any desired volGFG-809110.

   The adjusted signal volGFG-809110 is applied to the output circuit with its impedance converted, and then delivered through an output attenuator to the output terminal.

   The attenuator provides selectable attenuations of 0dB through -50dB in 10dB steps at 600Ω of output impedance.

2) Wien Bridge Oscillator Circuit

   The Wien bridge oscillator circuit with resistance elements may be switched over for 5 ranges by the FREQ. RANGE switch, and the variable capacitor controlled by the FREQUENCY dial.

   These elements provide means to vary the oscillating frequency continuously over 10 times its frequency on one range, so any desired frequency within the entire frequency range from 10Hz to 1MHz can be set.

   The buffer circuit for the oscillator circuit is composed of a 2 sGFG-809110 differential amplifier and an output sGFG-809110, employing an DC amplifier circuit.

   The output volGFG-809110 is fed back with positive polarity through the oscillator elements to form an oscillating circuit; while it is also fed back with negative polarity through the non-linear thermistor to stabilize the amplitude.低頻信號(hào)發(fā)生器GFG-809110

3) Square wave shaping circuit

   The square wave shaping circuit is a Schmit-trigger circuit in which the sine wave signal from the oscillator circuit is shaped into a square wave. Schmit-trigger circuit and a buffer amplifier providing sufficient rising and falling characteristics

4) Output circuit

   The output circuit converts the impedance of oscillating signal from the OUTPUT control and feeds the signal to the output attenuator at a low impedance. SEPP-OCL circuit is employed to provide sufficient low output impedance characteristics over the range from DC to 1MHz

5) Output Attenuator

   The 6-positions output attenuator selects attenuations of 0dB to -50dB in 10dB steps. At the 0dB position with the OUTPUT control turned fully clockwise, the output volGFG-809110 (sine wave at no-load time) is more than 5Vrms.

   The output impedance is rated at around 600Ω and the attenuation accuracy is as high as ± 1.0dB at 600Ω load.

6) Power supply

   The power supply circuit is powered by AC 110V/220V and delivers DC ± 24V sufficiently stabilized by large capacity smoothing capacitors and a volGFG-809110 stabilizer.

 

 

4. PANEL CONTROLS AND THEIR FUNCTIONS

   The table below describes the functions of panel controls. Refer to panel diagram on page 4

   FRONT PANEL

   1. DIAL POINTER

   This pointer indicates frequencies on the dial scale

   2.DIAL SCALE

   This dial is calibrated with graduations of 10-100 to indicate oscillating frequencies

   3. FREQUENCY DIAL

   This dial adjusts oscillating frequencies. Frequencies can be read by multiplying the reading on the dial scale by magnification of FREQ. RANGE.

   4. ATTENUATOR

   6-position output attenuator selects attenuations of 0dB to -50dB in 10dB steps.

   5. SYNC

   External synchronizing signal input terminals for GND for connection of synchronizing signal to the instruments.

   6. OUTPUT

   Output terminal used for both sine wave and square wave

   7. FREQ. RANGE

   Oscillating frequency range selector switch which selects the ranges in 5 steps as follows:

   X1       10Hz-100Hz

   X10      100Hz-1KHz

   X100     1KHz-10KHz

   X1K     10KHz-100KHz

   X10K    100KHz-1MHz

   8. WAVE FORM

   Output waveform selector switch. When pressed to “’ output signal is sine wave. When pressed to “” the signal is square wave.

   9. AMPLITUDE

   Amplitude adjuster to continuously vary the amplitude of output volGFG-809110

   10. POWER  Switch turns on the power when pressed

   11.VOLGFG-809110 SELECTOR  110V/220V selection

   12. AC INPUT TERMINAL

   13. FUSE SOCKET

14. This lamp ( light emitting diode) lights when POWER switch (10) is ON.

 

5. OPERATING INSTRUCIONS

  1) Start-up

    First check that the fuse (13), then connect the supplied AC  power cord to your AC outlet. Press the power switch (10) and the pilot lamp (14) will light indicating that the unit is ready for operation. Allow 3 minutes for the unit to warm up so that it is stabilized.

  2)Waveform selection

    Press the WAVE FORM switch (8) to “~” position to obtain sine waves. Press the switch to the “” position for square waves.

  3)Frequency selection

   First set the FREQ. RANGE switch (7) to the desired range, then set the frequency dial(3) so that the dial pointer(1) indicates your frequency.

Example: suppose you want to select a frequency of 1.5KHz, then proceed as follows:

1. Set FREQ. RANGE switch(7) to X 100.

2. by using the frequency dial, set the dial pointer(1) to “15” on the dial scale.

The frequency thus selected is:

15×00=1500(Hz)=1.5( KHz)

   4) Adjustment of output volGFG-809110

   The output volGFG-809110 from OUTPUT terminal (6) either sine wave or square wave, can be continuously varied by AMPLITUDE(9) and stepped down by ATTENUATOR (4)

 

Example: To adjust output volGFG-809110 to 10mV rms, proceed as follows:

1. Connect a voltmeter (e.g. TVT-321) capable of measuring AC  1V rms to OUTPUT terminal (6)

2. Set ATTENUATOR (4) to 0dB and then adjust AMPLITUDE (9) until the voltmeter indicates 1Vrms (6)

3. Set ATTENUATOR (4) to -40dB. The voltmeter indicates about OV, while a volGFG-809110 of 10mVrms appears at OUTPUT terminal (6)

 低頻信號(hào)發(fā)生器GFG-809110

5) USE of Synchronizing input terminal (instrument is between 990Hz and 1010Hz)

   By applying an external sine wave signal to SYNC terminal (5), the oscillating frequency can be synchronized to the external signal. Synchronizing range is increased in proportion as the input volGFG-809110 is increased as shown in Fig.3, indicating that the synchronizing range is about 1% per input volGFG-809110 of 1V.

 

Example: Suppose that the input signal volGFG-809110 is 1Vrms and the oscillating frequency of GENERATOR is between 990Hz and 1010Hz(1KHz±1KHz×1%/v×1V=1KHz±1KHz×0.01), the frequency can be synchronized with 1KHz of the input signal.

   Note that too high synchronizing signal volGFG-809110 will affect the amplitude and distortion factor, and care must therefore be taken when the signal volGFG-809110 is higher than 3Vrms. Also, note that if the synchronizing signal is largely deviated the distortion factor. It is therefore advisable that the oscillating frequency be first synchronized with a low input signal volGFG-809110 (less than 1Vrms) and then the volGFG-809110 be increased.

 

 

 

6. APPLICATIONS

1) Using as sine wave oscillator

   As a sine wave oscillator, features can be noted as below.

1.1 Low distortion factor can be obtained for measurement of distortion characteristic of amplifier.

1.2 As the unit working on wide bandwidth, it can be used for measurement of frequency characteristic of amplifier.

1.3 The built-in high accuracy attenuator permits measurement of amplifier gain.

1.4 Can be used as a signal source of impedance bridge.

2)Measurement of amplifier gain

   An example of measurement of amplifier gain is described below

   First connect the instrument, amplifier to be tested and AC volt-meter as shown in Fig.4

2.1Adjust ATTENUATOR (4) and AMPLITUDE(9) so that AC voltmeter indicates the rated output (supposed to be 1 Vin this example) of the amplifier. To facilitate the measurement, it is advisable to set ATTENUATOR(4) as low as possible. Assume that ATTENUATOR (4) is set -50dB for the rated output.

2.2 Disconnect the amplifier and connect the AC voltmeter to instrument to measure the output volGFG-809110. Note that the use of ATTENUATOR (4) eliminates the need for connecting a high sensitivity voltmeter. If ATTENUATOR(4) is set to 0dB and the voltmeter indicates 2V, it means that the input volGFG-809110 of the amplifier is 50dB below 2V. Therefore, the gain obtained is as follows:

 

3) Measurements of phase characteristic

   Connect the instrument and an oscilloscope to the amplifier to be tested as shown in Fig5. If there is no phase shift about the output signal of the amplifier, the oscilloscope will display a straight line as shown in Fig. 5A. If the straight line on the oscilloscope is curved at its top and bottom sections as shown in Fig.5B, it indicates that the output signal of amplifier is suffering from an amplitude distortion. In this case, reduce the output level of instrument a little to vary the frequency. This causes the straight line on the oscilloscope to expand gradually to turn into an ellipse. By utilizing the configuration of this ellipse. The phase shift can be calculated as follows:

   First, measure the maximum horizontal deflection and suppose that this deflection is”X” and that the section at which the ellipse crosses the horizontal axis is “X, as show in Fig.6. And, the phase shift angle θ is given by the following

 

Find from the table of trigonometric functions and the value obtained gives the angle of phase shift.

 

4)  Using as square wave oscillator

    The instrument features excellent rising and falling characteristics (120ns as standard characteristic.) it has no coupling capacitors in the output sGFG-809110, so the sag (deflection of top section) is as low as 5% at 50Hz. By applying such a good square wave to an amplifier input, various characteristics of amplifier can be observed on an oscilloscope. To test an amplifier proceed as follows:

4.1 connect the instrument, an amplifier to be tested and an oscilloscope as shown in Fig7.

4.2 Press WAVE FORM (8) to the “” position to obtain square waves of appropriate frequency and amplitude.

4.3 During the test, change the frequency as necessary. The relationship between waveforms and amplifier characteristics is shown in Fig.8

 

GFG-809110低頻信號(hào)發(fā)生器

公司已發(fā)展成為一家集研發(fā)、生產(chǎn)、銷售、售后于一體的企業(yè)。公司以“高效服務(wù),誠(chéng)信創(chuàng)新”為經(jīng)營(yíng)理念,取得了用戶的*認(rèn)可。本著“質(zhì)量是生命,服務(wù)是根基”的創(chuàng)業(yè)理念,博采眾長(zhǎng),堅(jiān)持以品質(zhì)為先,以服務(wù)取勝!

 

公司銷售網(wǎng)絡(luò)遍布全國(guó),為國(guó)內(nèi)外企業(yè)用戶提供Zui大化壓縮商品物流環(huán)節(jié),大大降低用戶采購(gòu)成本,力爭(zhēng)成為業(yè)內(nèi)工業(yè)品集成供應(yīng)商。

 

公司以技術(shù)為先導(dǎo),在得到廣大用戶認(rèn)可的同時(shí),業(yè)務(wù)能力也得到了發(fā)展,積累了豐富的行業(yè)經(jīng)驗(yàn)力,經(jīng)營(yíng)規(guī)模不斷擴(kuò)大,不斷成長(zhǎng)為一家綜合性的供應(yīng)商。

 

公司團(tuán)隊(duì)口號(hào):我們是細(xì)分領(lǐng)域?qū)<遥√貏e能吃苦!特別能學(xué)習(xí)!特別能戰(zhàn)斗!

 

對(duì)用戶的鄭重承諾是:莫因事小而不為之,莫因事煩而不愿為之。

 

隨著公司的不斷成長(zhǎng)、壯大,公司將繼續(xù)以服務(wù)社會(huì)為己任,我們始終本著“質(zhì)量是生命,服務(wù)是根基”的創(chuàng)業(yè)理念,堅(jiān)持以品質(zhì)為先,以服務(wù)取勝!

 

公司擁有專業(yè)的銷售工程師和強(qiáng)大的技術(shù)支持,優(yōu)質(zhì)的售后服務(wù)隊(duì)伍為用戶提供快捷、周到的服務(wù),消除您一切后顧之憂。我們深信,只有站在用戶的立場(chǎng),為用戶提供更好服務(wù)。以支持用戶的業(yè)務(wù)和發(fā)展,才能終獲得雙羸!

 

公司以其化的平臺(tái),打造高效能供應(yīng)鏈體系,配套大型空港倉(cāng)儲(chǔ)物流中心,為用戶提供強(qiáng)有力的供貨保障。

 

“下道工序的要求是對(duì)上道工序的命令”,用戶是我們終的下道工序,所以滿足用戶的需求 “有求必應(yīng)” 是一切工作的出發(fā)點(diǎn)和核心。

 

“科技為本、*yi、用戶至上、合作共贏”是公司一貫的宗旨。公司將嚴(yán)守承諾,積極進(jìn)取,進(jìn)一步加大研發(fā)投入,開發(fā)更好的產(chǎn)品與用戶共享,并謁誠(chéng)為廣大用戶提供jia的服務(wù)。

 

讓我們一路同行,攜手走向更加美好的明天!

 

SM-30磁化率儀在地理和地質(zhì)方面用途廣泛,*的靈敏度為10–7SI,小得可放在襯衫口袋里,重量輕,深受擁護(hù)喜愛。SM-30SM-20的升級(jí)版,更新穎,更精確。

SM-30特別用在野外地質(zhì)勘探和快速實(shí)驗(yàn)室分析,對(duì)巖石或巖心樣品進(jìn)行分析和分類。能測(cè)出順磁性、反磁性、鐵磁性巖石的細(xì)微差別并精確地給出磁化率。使用了傳統(tǒng)的傳感器和新的信號(hào)處理方法保證儀器處于lǐng先地位。

SM-30的六個(gè)測(cè)量模式在工作狀態(tài)下可切換。兩個(gè)是基本模式,兩個(gè)是補(bǔ)償模式,一個(gè)是掃描模式,一個(gè)是平均模式。

自動(dòng)調(diào)整測(cè)量,非常簡(jiǎn)單的三鍵控制,單手可操作,一個(gè)用于測(cè)量,一個(gè)用于貯存,一個(gè)用于存檔。其它操作可使用電腦來完成,如給出測(cè)點(diǎn)說明,貯存測(cè)量數(shù)據(jù)以便進(jìn)一步處理。鋰電池以及自動(dòng)關(guān)機(jī)功能配合,可在不換電池的情況下長(zhǎng)期工作。

 

技術(shù)參數(shù)

靈敏度:10 – 7SIunit s

工作頻率:8KHz

測(cè)量時(shí)間:每點(diǎn)不長(zhǎng)于5秒

數(shù)字顯示:4數(shù)位LCD

控制:3個(gè)控制鍵

測(cè)量范圍:0.000999×        1/1000SIunits,自動(dòng)調(diào)整測(cè)量范圍

內(nèi)存:250個(gè)測(cè)量數(shù)據(jù),更大內(nèi)存可依附于電腦

傳感器:空心線圈+8KHz LC振子,直徑50mm。在20mm范圍內(nèi)可獲取90%的信號(hào)

電池:2塊3V鋰電池CR2430(正常工作時(shí)間為80小時(shí))

尺寸:100×65×25mm

操作溫度:-20℃ 到 +50℃

會(huì)員登錄

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
在線留言

會(huì)員登錄

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:
熱線電話 在線詢價(jià)
土默特右旗| 涡阳县| 葵青区| 石河子市| 双柏县| 彭山县| 邳州市| 贡嘎县| 汝州市| 延川县| 闻喜县| 义乌市| 阜新| 天气| 灵寿县| 兰溪市| 石城县| 太白县| 藁城市| 舒兰市| 桐庐县| 锦州市| 汤原县| 安顺市| 金沙县| 治县。| 德安县| 巩义市| 巴里| 钦州市| 开江县| 黄梅县| 惠安县| 民勤县| 射洪县| 莆田市| 大姚县| 密云县| 吉安市| 察隅县| 徐州市|