稱重儀表也叫稱重顯示控制儀表,是將稱重傳感器信號(或再通過重量變送器)轉換為重量數(shù)字顯示,并可對重量數(shù)據(jù)進行儲存、統(tǒng)計、打印的電子設備,常用于工農(nóng)業(yè)生產(chǎn)中的自動化配料,稱重,以提高生產(chǎn)效率。
美國Transducer Techniques DPM-3是一款智能插拔式TEDS IEEE 1451.4儀表,連接稱重傳感器或者扭矩傳感器TEDS接頭,可自動校準。
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.
Approved
Plug & Play IEEE 1451.4 Compliant
Digital and or analog triggering
Setup by front panel push buttons
Peak / Valley hold and auto tare
Plug-in screw terminals
Automatic, adaptive digital filtering
60 Conversions per second for fast control
response and True peak reading
Scalable to 5 digits engineering units to
±.99,999
Worldwide input power 85 to 264 VAC
and 90 to 300 VDC
Isolated 5, 10, or 24 VDC output provides
load cell excitation
Input Voltage rating (standard) 85-264 Vac or 90-300 Vdc Input Voltage rating (low voltage option) 12-32 Vac or 10-48 Vdc Power Line Frequency DC and 47-63 Hz Power Consumption, Max 5 Watts Recommended Load 350-10K ohm bridge Voltage & Current Levels (jumper selectable) 5 Vdc ±5%, 100 mA max 10 Vdc ±5%, 120 mA max 24 Vdc ± 5%, 40 mA max Excitation Output Ripple 100 mVp max Isolation from power and outputs 250 Vac Insulation dielectric strength to power and outputs 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min Isolation to signal common 50 Vdc Power to Relay Option Powered by meter Setpoint Setup Via front panel pushbuttons or RS232/485 Update Rate 56/s at 60 Hz, 47/s at 50 Hz Response to input signal (min) Display update rate Input Signal (selectable) Filtered or unfiltered input signal Actuation Modes (selectable) Above or below setpoint, latching or non-latching, disabled Output Time Delay (selectable) 1 to 128 readings Front Panel Enable / Lockout Modes (selectable) 1) Display and change setpoints 2) Display but do not change setpoints 3) Neither display nor change setpoints Alarm Status Indication 2 or 4 red LED lamps Status Indication Setup (selectable) Lit when output is ON or OFF, or disabled | Form C, SPDT Relay Output: AC Rating 8A @ 240 Vac DC Rating 8A @ 24 Vdc Isolation rating between signal common and contacts 250 Vac Insulation dielectric strength between signal common and contacts 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min Form A, SPST Solid State Relay Output: AC Rating 120 mA @ 140 Vac DC Rating 120 mA @ 180 Vdc Isolation rating between signal common and contacts 250V ac Insulation dielectric strength between signal common and contacts 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min Power to Analog Output Option Powered by meter Output Levels 0-20 mA, 4-20 mA, 0-10V, -10 to +10V Voltage Compliance, 0-20 mA Output 12V (0-600 Ohm load) Current Compliance, 0-10V, -10 to +10V Output 2 mA (5 kOhm or higher load) Accuracy Meter input accuracy ±0.02% of full scale analog output Resolution 16 bit (1 part in 65,536) Response Time 50/60Hz update rate Scaling of Reading for Zero Output -99,999 to +99,999 Scaling of Reading for Full Scale Output -99,999 to +99,999 Isolation rating between signal common and analog output 250V ac Insulation dielectric strength between signal common and analog output 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min Control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) |
訂貨型號
DPM-3 N/A Digital Panel Meter
Options
DPM-3-OPT-C N/A Dual Relay Board
DPM-3-OPT-H N/A Analog Output Board
DPM-3-OPT-T N/A Serial Data Board (RS-232)
DPM-3-OPT-TRS485 N/A Serial Data Board (RS-485)
DPM-3-OPT-U N/A Serial Data Board (USB)
DPM-3-OPT-URS485 N/A Serial Data Board (USB & RS485)
DPM-3-OPT-V N/A Low Voltage Power Supply
配件
DPM-3-AD9 N/A Adapter Connector
DPM-3-SPC N/A DPM-3-SPC Splash Proof Cover
USB-2.0A/B N/A USB 2.0 A/B 10ft Cable
DPM-3-RJ11AD9 N/A RS232 Cable
DPM-3-PC6 N/A 6 Foot Power Cable
DPM-3-PC12 N/A 12 Foot Power Cable
DPM-3-TRES N/A TEDS Reader Editor Software
DPM-3-DLS N/A Data Logging Software