產(chǎn)品簡介
詳細(xì)介紹
ProPac WAX 蛋白質(zhì)分析柱保護(hù)柱戴安離子色譜柱耗材美國戴安Dionex
ProPac SAX-10 Strong Anion-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications | |
---|---|
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating conditions | 60 °C Recommended operating temperature: <40 °C |
Typical operating conditions | UV detection at 1 mL/min Recommended flow rate: 1 mL/min |
phase compatibility | pH 2–12; 80% compatible with acetonitrile, acetone, methanol. Compatible with nonionic and zwitterionic detergents. Incompatible with anionic detergents. |
Resin composition | 10-μm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the quaternary ammonium functional groups. |
Anion-exchange capacity | < 100 μg protein on-column, depending upon the protein (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
ProPac WAX-10 Weak Anion-Exchange Column for the High-Resolution Analysis of Protein Variants Specifications | |
---|---|
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating temperature | 60 °C Recommended operating temperature: <40 °C |
Typical operating conditions | UV detection at 1 mL/min Recommended flow rate: 1 mL/min |
phase compatibility | pH 2–12; 80% compatible with acetonitrile, acetone, methanol. Compatible with nonionic and switterionic detergents. Incompatible with anionic detergents. |
Resin composition | 10-μm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the tertiary amine functional groups. |
Anion-exchange capacity | < 100 μg protein on-column, depending upon the protein (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
SAX Analytical Columns | |
---|---|
ProPac SAX-10 Analytical Column (2 x 250 mm) | 063448 |
ProPac SAX-10 Analytical Column (4 x 250 mm) | 054997 |
ProPac SAX-10HT Analytical Column (4 x 50 mm) | 078990 |
ProPac SAX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin) | SP5729 |
ProPac SAX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin) | SP5730 |
ProPac SAX-10 Semi-Preparative Column (9 x 250 mm) | 063703 |
ProPac SAX-10 Semi-Preparative Column (22 x 250 mm) | SP5594 |
WAX Analytical Columns | |
---|---|
ProPac WAX-10 Analytical Column (2 x 250 mm) | 063464 |
ProPac WAX-10 Analytical Column (4 x 250 mm) | 054999 |
ProPac WAX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin) | SP5731 |
ProPac WAX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin) | SP5732 |
ProPac WAX-10 Semi-Preparative Column (9 x 250 mm) | 063707 |
ProPac WAX-10 Semi-Preparative Column (22 x 250 mm) | SP5598 |
WAX Guard Columns | |
---|---|
ProPac WAX-10G Guard Column (2 x 50 mm) | 063470 |
ProPac WAX-10G Guard Column (4 x 50 mm) | 055150 |
SAX Guard Columns | |
---|---|
ProPac SAX-10G Guard Column (2 x 50 mm) | 063454 |
ProPac SAX-10G Guard Column (4 x 50 mm) | 054998 |
ProPac WAX 蛋白質(zhì)分析柱保護(hù)柱戴安離子色譜柱耗材美國戴安Dionex,