上海希言科學(xué)儀器有限公司>>美國戴安Dionex>> 美國戴安 P/N: 071987Dionex Acclaim Carbamate LC Column 液相色譜柱

Dionex Acclaim Carbamate LC Column 液相色譜柱

返回列表頁
  • Dionex Acclaim Carbamate LC Column 液相色譜柱
  • Dionex Acclaim Carbamate LC Column 液相色譜柱
收藏
舉報(bào)
參考價(jià) 面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 型號 美國戴安 P/N: 071987
  • 品牌 DIONEX/英國
  • 廠商性質(zhì) 代理商
  • 所在地 上海
在線詢價(jià) 收藏產(chǎn)品 加入對比 查看聯(lián)系電話

更新時(shí)間:2018/04/30 13:58:32瀏覽次數(shù):528

聯(lián)系我們時(shí)請說明是化工儀器網(wǎng)上看到的信息,謝謝!

同類優(yōu)質(zhì)產(chǎn)品

更多產(chǎn)品

產(chǎn)品簡介

戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。

詳細(xì)介紹

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 μm, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 μm, 4.6 × 150 mm column saves time and increases sample throughput; the 3 μm, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 μm, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 μm columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技術(shù)參數(shù):



Acclaim Carbamate Column Specifications
Column chemistryProprietary alkyl group
Operating pressure limit (recommended)6000 psi (4000 psi)
Operating pH range (recommended)2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended)0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats

訂購信息:



Analytical Columns
Acclaim RSLC Carbamate, 2.2μm Analytical (2.1 x 150mm)075596
Acclaim RSLC Carbamate, 2.2μm Analytical (2.1 x 100mm)075597
Acclaim Carbamate, 5μm Analytical (4.6 x 250mm)072924
Acclaim Carbamate, 3μm Analytical (4.6 x 150mm)072925
Acclaim Carbamate, 3μm Analytical (3.0 x 150mm)072926
Acclaim Carbamate, 3μm Analytical (2.1 x 150mm)072927
Guard Columns
Acclaim Carbamate, 3μm Guard (4.6 x 10mm) 2ea (Use Holder V-2)072928
Acclaim Carbamate, 3μm Guard (3.0 x 10mm) 2ea (Use Holder V-2)072929
Acclaim Carbamate, 3μm Guard (2.1 x 10mm) 2ea (Use Holder V-2)072930
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188