性猛交XXXX乱大交派对,四虎影视WWW在线观看免费 ,137最大但人文艺术摄影,联系附近成熟妇女

| 注冊| 產(chǎn)品展廳| 收藏該商鋪

行業(yè)產(chǎn)品

當(dāng)前位置:
北京國儀精測技術(shù)有限公司>>商機(jī)中心>>供應(yīng)列表>>V-Sorb 4800-Langmuir isotherm specific surface area bjh method pore size distribution
[供應(yīng)]V-Sorb 4800-Langmuir isotherm specific surface area bjh method pore size distribution
舉報
返回列表頁
  • V-Sorb 4800-Langmuir isotherm specific surface area bjh method pore size distribution
貨物所在地:
北京北京市
更新時間:
2023-12-12 21:00:06
有效期:
2023年12月12日 -- 2024年6月12日
已獲點(diǎn)擊:
1012
在線詢價 收藏產(chǎn)品

(聯(lián)系我們,請說明是在 化工儀器網(wǎng) 上看到的信息,謝謝?。?/p>

產(chǎn)品簡介

Gold APP Instruments specialized in BET surface area, BJH pore size, Langmuir surface area, pore size distribution, external surface area, pore volume, heliun true density, adsorption and desorption.

詳細(xì)介紹

V-Sorb 4800 surface area and porosimetry analyzer introduction

V-Sorb 4800 is researched by Gold APP Instruments for surface area and pore size testing by utilizing static volumetric principle. Compared with other competitors analyzers, multi pioneered technologies make its performance much better. Heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level among global competitors. Equipment designed from the user perspective and with fully automated operation system, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong its life. High cost performance of V-Sorb 4800 easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requirements.

 

V-Sorb 4800 surface area and porosimetry analyzer parameters

Analysis Method: static volumetric nitrogen adsorption principle

Versatility: Adsorption and desorption isotherms, Single and multi-point BET surface area, Langmuir method surface area, Average particle diameter estimation, t-plot external surface area, True density analysis, BJH total pore volume and pore size distribution analysis, t-plot method micropore analysis, MP micropore, Dubinin-Radushkevich (DR) and Dubinin-Astakhov (DA) micropore surface area

Measuring Ranges: 0.01m2/g to no known upper limit (surface area)

              0.35 to 400nm (pore size)

Accuracy: repeatability errors ≤1%

Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life

Coolant Level Prober: V-Sorb original coolant level probe system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, compley eliminate the analysis errors caused by dead volume change

Sample Treatment: the whole treatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night

Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument’s stability and life

Sample Ports: 4 samples analyzing and 4 samples degassing concurrently

Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)

Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)

Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.995

Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)

Sample Types: powders, particle, fiber, flakes and other species

Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO, CO2, C4H10 etc. non-corrosive gases are optional

Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability

Data Reduction: Windows®-based independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports

 

V-Sorb 4800 surface area and porosimetry analyzer features

A: Vacuum System

1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.

3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

B: Control System

1. Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.

2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.

C. Measures for Improving Accuracy

1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).

2. 0-10Torr (optional) and 0-1000Torr dual transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.

4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, compley eliminate the analysis errors caused by dead volume change.

5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.

D. Data Acquisition and Reduction

1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 and USB modes.

2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.

 

V-Sorb 4800 surface area and porosimetry analyzer application

1. Super micro powder, nanomaterials, particle and fiber shaped surface area analysis.

2. Product quality control for powder species related corporations.

3. Research institutes, universities for BET theory teaching.

4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.

5. Other researches concern surface area performance.

 

Contact info:

Web: www.jinaipu。。com/ www.app-one。。com.cn

: sales@jinaipu.com

.: 0086-10-82133318 Ext.810

0086-10-82118197

: 0086-

IMs:

Skype: Gold-APP-Instruments

Yahoo: goldappinstruments@ymail.com

Gtalk: goldappinstruments2008

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~
二維碼 意見反饋
在線留言
纳雍县| 新邵县| 洛阳市| 曲麻莱县| 杭锦旗| 敦化市| 美姑县| 克山县| 惠州市| 筠连县| 岚皋县| 东乡族自治县| 石城县| 远安县| 菏泽市| 江油市| 尉氏县| 乐安县| 新沂市| 孟连| 自治县| 札达县| 丹棱县| 漳浦县| 顺义区| 远安县| 印江| 德化县| 绿春县| 金寨县| 潮安县| 兰坪| 芮城县| 台前县| 凌云县| 开远市| 延吉市| 奉贤区| 巴彦淖尔市| 诸城市| 凤台县|