您好, 歡迎來到化工儀器網(wǎng)! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:廈門慧嘉生物科技有限公司>>技術(shù)文章>>CSB-E05176h人白三烯E4(LTE4)english說明書
1
Human Leukotriene E4 (LTE4)
ELISA Kit
Catalog No. CSB-E05176h
(96T)
This immunoassay kit allows for the in vitro quantitative determination of human LTE4
concentrations in serum, plasma and other biological fluids.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
CUSABIO BIOTECH CO., LTD.
http://www.cusabio.com/ http://www.cusabio.cn/
: cusabio@cusabio.com cusabio@cusabio.cn
2
INTRODUCTION
Leukotrienes are fatty molecules of the immune system that contribute to inflammation in
asthma and bronchitis. Leukotriene antagonists are used to treat asthma and bronchitis.
Leukotrienes are naturally produced eicosanoid lipid mediators. Leukotrienes use both
autocrine signalling and paracrine signalling to regulate the body's response. Leukotrienes are
produced in the body from arachidonic acid by the enzyme 5-lipoxygenase. Their production
usually accompanies the production of histamine.
Leukotrienes produced within a cell convey signals that either act on the cell producing them
(autocrine signalling) or on neighboring cells (paracrine signalling) to regulate the immune
response. Leukotrienes are produced from arachidonic acid by the enzyme 5-lipoxygenase.
Their production usually accompanies the production of histamine.
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an antibody specific to LTE4.
Standards or samples are then added to the appropriate microtiter plate wells with a
biotin-conjugated polyclonal antibody preparation specific for LTE4 and Avidin conjugated to
Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB
(3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that
contain LTE4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change
in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid
solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ±
2 nm. The concentration of LTE4 in the samples is then determined by comparing the O.D. of
the samples to the standard curve.
DETECTION RANGE
12.5 ng/ml-800 ng/ml. The standard curve concentrations used for the ELISA’s were 800 ng/ml,
400 ng/ml, 200 ng/ml, 100 ng/ml, 50 ng/ml, 25 ng/ml, 12.5 ng/ml.
SPECIFICITY
This assay recognizes human LTE4. No significant cross-reactivity or interference was
observed.
SENSITIVITY
The minimum detectable dose of human LTE4 is typically less than 3 ng/ml.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest
protein concentration that could be differentiated from zero.
MATERIALS PROVIDED
3
Reagent Quantity
Assay plate 1
Standard 2
Sample Diluent 1 x 20 ml
Biotin-antibody Diluent 1 x 10 ml
HRP-avidin Diluent 1 x 10 ml
Biotin-antibody 1 x 120µl
HRP-avidin 1 x 120µl
Wash Buffer
1 x 20 ml
(25×concentrate)
TMB Substrate 1 x 10 ml
Stop Solution 1 x 10 ml
STORAGE
1. Unopened test kits should be stored at 2-8°C upon receipt and the microtiter plate should be
kept in a sealed bag. The test kit may be used throughout the expiration date of the kit.
Refer to the package label for the expiration date.
2. Opened test kits will remain stable until the expiring date shown, provided it is stored as
prescribed above.
3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of
0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
REAGENT PREPARATION
Bring all reagents to room temperature before use.
1. Wash Buffer If crystals have formed in the concentrate, warm up to room temperature
and mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer
Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
2. Standard Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution
produces a stock solution of 800 ng/ml. Allow the standard to sit for a minimum of 15
minutes with gentle agitation prior to making serial dilutions. The undiluted standard
serves as the high standard (800 ng/ml). The Sample Diluent serves as the zero standard
(0 ng/ml).
3. Biotin-antibody Dilute to the working concentration using Biotin-antibody
Diluent(1:100), respectively.
4. HRP-avidin Dilute to the working concentration using HRP-avidin Diluent(1:100),
respectively.
4
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face,
and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
Microplate reader capable of measuring absorbance at 450 nm, with the correction
wavelength set at 540 nm or 570 nm.
Pipettes and pipette tips.
Deionized or distilled water.
Squirt bottle, manifold dispenser, or automated microplate washer.
SAMPLE COLLECTION AND STORAGE
Cell Culture Supernates Remove particulates by centrifugation and assay immediay
or aliquot and store samples at -20° C. Avoid repeated freeze-thaw cycles.
Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes
before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediay or
aliquot and store samples at -20° C. Avoid repeated freeze-thaw cycles.
Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge
for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot
and store samples at -20° C. Avoid repeated freeze-thaw cycles.
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all
samples, standards, and controls be assayed in duplicate.
1. Add 100µl of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate
for 2 hours at 37° C.
2. Remove the liquid of each well, don’t wash.
3. Add 100µl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C.
Biotin-antibody working solution may appear cloudy. Warm up to room temperature and
mix gently until solution appears uniform.
4. Aspirate each well and wash, repeating the process three times for a total of three washes.
Wash by filling each well with Wash Buffer (200µl) using a squirt bottle, multi-channel
pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is
essential to good performance. After the last wash, remove any remaining Wash Buffer by
aspirating or decanting. Invert the plate and blot it against clean paper towels.
5. Add 100µl of HRP-avidin working solution to each well. Cover the microtiter plate with a
5
new adhesive strip. Incubate for 1 hour at 37°C.
6. Repeat the aspiration and wash three times as step 4.
7. Add 90µl of TMB Substrate to each well. Incubate for 30 minutes at 37°C. Keeping the
plate away from drafts and other temperature fluctuations in the dark.
8. Add 50µl of Stop Solution to each well. If color change does not appear uniform, gently
tap the plate to ensure thorough mixing.
9. Determine the optical density of each well within 30 minutes, using a microplate reader set
to 450 nm.
CALCULATION OF RESULTS
Average the duplicate readings for each standard, control, and sample and subtract the average
zero standard optical density. Create a standard curve by reducing the data using computer
software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative,
construct a standard curve by plotting the mean absorbance for each standard on the y-axis
against the concentration on the x-axis and draw a best fit curve through the points on the
graph. The data may be linearized by plotting the log of the LTE4 concentrations versus the log
of the O.D. and the best fit line can be determined by regression analysis. This procedure will
produce an adequate but less precise fit of the data. If samples have been diluted, the
concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
The kit should not be used beyond the expiration date on the kit label.
Do not mix or substitute reagents with those from other lots or sources.
It is important that the Calibrator Diluent selected for the standard curve be consistent with
the samples being assayed.
If samples generate values higher than the highest standard, dilute the samples with the
appropriate Calibrator Diluent and repeat the assay.
Any variation in Standard Diluent, operator, pipetting technique, washing technique,
incubation time or temperature, and kit age can cause variation in binding.
This assay is designed to eliminate interference by soluble receptors, binding proteins, and
other factors present in biological samples. Until all factors have been tested in the
Quantikine Immunoassay, the possibility of interference cannot be excluded.
TECHNICAL HINTS
When mixing or reconstituting protein solutions, always avoid foaming.
To avoid cross-contamination, change pipette tips between additions of each standard level,
between sample additions, and between reagent additions. Also, use separate reservoirs for
each reagent.
6
When using an automated plate washer, adding a 30 second soak period following the
addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may
improve assay precision.
To ensure accurate results, proper adhesion of plate sealers during incubation steps is
necessary.
Substrate Solution should remain colorless until added to the plate. Keep Substrate
Solution protected from light. Substrate Solution should change from colorless to
gradations of blue.
Stop Solution should be added to the plate in the same order as the Substrate Solution. The
color developed in the wells will turn from blue to yellow upon addition of the Stop
Solution. Wells that are green in color indicate that the Stop Solution has not mixed
thoroughly with the Substrate Solution.
慧嘉生物您實(shí)驗(yàn)身邊的好伙伴
為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”
AssayBiotech CUSABIO Immunoway Santa Abcam Cst jackson Pierce Sigma Amresco Qiagen Cayman abnova millipore invitrogen merk ebioscience prospec
LifeSpan BD 歡迎廣大客戶咨詢,另有大量宣傳海報(bào)和小禮品贈(zèng)送。
:www.biohj.com
:382603320 1284882975
請(qǐng)輸入賬號(hào)
請(qǐng)輸入密碼
請(qǐng)輸驗(yàn)證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。