●產(chǎn)品特點(diǎn) |
☆三種測(cè)試功能可供選擇:ACW,DCW,IR |
☆可與接地阻抗測(cè)試儀連接使用 |
☆可同時(shí)進(jìn)行100臺(tái)的連線測(cè)試 |
☆開(kāi)機(jī)自檢功能,可于測(cè)試前進(jìn)行儀器各項(xiàng)功能是否正常 |
☆鍵盤(pán)鎖定功能,安全鎖定功能 |
☆內(nèi)建PLC Remote遙控介面 |
☆前面板軟體輸入校正 |
☆操作簡(jiǎn)單 |
☆體積小、重量輕 |
●技術(shù)參數(shù) |
MODEL | | | 7130 | 7132 | 7140 | 7142 |
AC WITHSTAND VOLTAGE | | | | | | | |
Output Rating | | 5KVAC/20mA |
| | | Range | Resolution | Accuracy |
Output Voltage,KVAC | 0-5.00 | 0.01 | ±( 2% of setting +5V ) |
Output Frequency | | 50Hz/60Hz±100ppm,User Selection |
Output Waveform | | Sine Wave,THD<2%( Resistion Load ),Crest Factor = 1.3-1.5 |
Output Regulation | | ±( 1% of output +5V ),F(xiàn)orm no load full load |
SETTINGS | | | | | | | | | |
Max-Limit AC Current,mA | 0-20.00 | 0.01 | ±( 2% of setting +2counts ) |
Min-Limit AC Current,mA | 0-9.999 | 0.001 | ±( 2% of setting +2counts ) |
Ramp Time,second | | 0-999.9 | 0.1 | ±( 0.1% + 0.05sec ) |
Dwell Time,second | 0,0.3-999.9 | 0.1 |
( 0=continuous ) |
Arc Detection | | 0,1-9 ranges ( 0=OFF,9 is the most sensitivity ) |
DC WITHSTAND VOLTAGE(7140,7142 ONLY) | | | | | |
Output Rating | | 6KVDC/7500uA |
Output Voltage,KVDC | 0-6.00 | 0.01 | ±( 2% of setting +5V ) |
Output Ripple | | < 5% ( 6KV/7500uA at Resistive Load ) |
SETTINGS | | | | | | | | | |
Max-Limit DC Current,uA | 0-7500 | 1 | ±( 2% of setting +2counts ) |
Min-Limit DC Current,uA | 0-999.9 | 0.1 | ±( 2% of setting +2counts ) |
Ramp Time,second | | 0.1-999.9 | 0.1 | ±( 0.1% + 0.05sec ) |
Dwell Time,second | 0,0.4-999.9 | 0.1 |
( 0=continuous ) |
Arc Detection | | 0,1-9 ranges ( 0=OFF,9 is the most sensitivity ) |
Discharge Time | | ≦200msec |
MODEL | | | 7130 | 7132 | 7140 | 7142 |
INSULATION RESISTANCE ( 7132,7142 ONLY ) | | | | | |
Output Rating | | 1KVDC/9999MW |
Output Voltage,VDC | | 30-1000 | 10 | ±( 2% of setting +3V ) |
SETTINGS | | | | | | | | | |
Max-Limit Resistance,MW | 0,1-9999(0=OFF ) | 1 | ±(2% of setting +2counts) at 500-1000VDC,1-1000M |
Min-Limit Resistance,MW | 1-9999 | 1 | ±(5% of setting +2counts) at 500-1000VDC,1000-9999M |
±(8% of setting +2counts) at 30-500VDC,1-1000M |
Ramp Time,second | | | 0.1-999.9 | 0.1 | ± ( 0.1% + 0.05sec ) |
Dwell Time,second | | | 0,1.0-999.9 | 0.1 |
Delay Time,second | 0,0.5-999.9 | 0.1 |
( 0=continuous ) |
GENERAL | | | | | | | | | |
Input Voltage AC | | 115/230VAC±15%,50/60Hz±5%,F(xiàn)use 3.15A Fast |
PLC Remote Control | Input: Test,Reset,Memory1.2.3,Interlock |
Output: Pass,F(xiàn)ail,Processing |
Interface( Option ) | RS485 Interface | | | | | | |
Memory | 10memories,3 steps/Memory |
Display | 128×64 Graphic LCD |
Safety | Built-in Smart GFI trip current 450uA max,HV shut dowm speed : <1mS |
Key Lock | To prevent unauthorized alteration of test parameters |
Calibration | Build-in software and external calibrated meters |
Verification | Build-in software driven verification menu to test fault detection circuits |
Alarm Volume Setting | | Range : 0-9;0=OFF,1 is softest volume,9 is loudest volume | | |
Environment | 0-40℃,20-80%RH |
Dimension/Net Weight | 215mm(W)×89mm(H)×370mm(D)/10Kg |
※Ordering Information※------------------------------------------------------------------------------------ |
7130 AC Withstand Voltage Tester |
7132 AC Withstand Voltage / Insulation Resistance Tester |
7140 AC/DC Withstand Voltage Tester |
7142 AC/DC Withstand Voltage / Insulation Resistance Tester |