主要特點(diǎn)和優(yōu)點(diǎn) 所有模塊 - 高達(dá)70 GHz的帶寬和5 ps的上升時(shí)間(10 - 90%)
- zui低的分析噪聲–60 GHz時(shí)450 μVRMS , 30 GHz時(shí)300 μVRMS
- 遠(yuǎn)程取樣器*1把采樣頭放到DUT附近,保證*的信號(hào)保真度
- 獨(dú)立的取樣器偏移校正功能,保證簡便地反嵌夾具和探頭
- 雙通道(80E01和80E06除外)
- 高精度微波連接器(3.5 mm, 2.92 mm, 2.4 mm和1.85 mm)
- 探頭支持(80E06除外)
TDR 模塊 - 15 ps反射真正差分全內(nèi)置TDR上升時(shí)間(12 ps入射),阻抗分辨率小于1 mm
- 高達(dá)50 GHz的高效、準(zhǔn)確、簡便易用、經(jīng)濟(jì)的S參數(shù)測量
應(yīng)用 - 串行數(shù)據(jù)應(yīng)用阻抗檢定和S參數(shù)測量
- 高級(jí)抖動(dòng)、噪聲和BER分析
- 通道和眼圖仿真和基于測量的Spice模型
80E10, 80E08 和80E04 - 高性能TDR/T測量
- 阻抗特征, 電感, 電容和S參數(shù)測量
- 傳輸線質(zhì)量, 阻抗和串?dāng)_
- 真正差分, 共模和單端測量
- 高效隔離故障
80E09, 80E07, 80E06, 80E01 - 高頻, 低噪聲信號(hào)采集
- 快速上升時(shí)間測量
- 抖動(dòng)分析和波形分析
80E03 和80E02 - 器件檢定, 傳輸質(zhì)量, 波形參數(shù)
- 小信號(hào)測量
*1集成在80E07 – 80E10上,80E01 – 80E04和80E06上選裝。 TDR 模塊: 80E10, 80E08 和80E04 80E10、80E08和80E04是雙通道時(shí)域反射計(jì)(TDR)取樣模塊,在80E10中提供了高達(dá)12 ps的入射上升時(shí)間和15 ps的反射上升時(shí)間(在80E08中提供了18 ps的入射上升時(shí)間,在80E04中提供了23 ps的入射上升時(shí)間)。這些模塊的每條通道都能夠生成一個(gè)用于TDR模式的快速階躍信號(hào);取樣模塊的采集部分監(jiān)測入射階躍和任何反射的能量??梢元?dú)立選擇每條通道的階躍極性。除獨(dú)立測試隔離線路外,它還可以對(duì)兩條耦合線路執(zhí)行差分或共模TDR或S參數(shù)測試。每條通道獨(dú)立階躍生成功能可以實(shí)現(xiàn)真正差分測量,保證了差分器件的測量準(zhǔn)確性。 80E10和80E08是全面集成的獨(dú)立式小型2米遠(yuǎn)程取樣器系統(tǒng),可以把采樣頭放在DUT附近,保證*的信號(hào)保真度。泰克為80E04提供了選裝的2米擴(kuò)展器。這些模塊使用TDR階躍驅(qū)動(dòng)一條線路(或在測量差分串?dāng)_時(shí)驅(qū)動(dòng)線路對(duì)),同時(shí)使用另一條通道監(jiān)測第二條線路(或在測量差分串?dāng)_時(shí)使用另一個(gè)模塊),檢定串?dāng)_。8200和8000系列主機(jī)上的“濾波器”功能可以與TDR或串?dāng)_測量一起使用,以較低的邊沿速率檢定預(yù)計(jì)的系統(tǒng)性能。 所有模塊擁有獨(dú)立的入射階躍和接收機(jī)偏移校正功能,消除了測量夾具和探頭的影響,可以更快、更簡便地反嵌測試夾具。80E10 取樣模塊提供了7 ps的采集上升時(shí)間及高達(dá)50 GHz的用戶可選同等帶寬(50, 40和30 GHz設(shè)置)。80E08的取樣帶寬是30 GHz (用戶可以選擇30和20 GHz設(shè)置),80E04的取樣帶寬是20 GHz。20 GHz P8018單端探頭和18 GHz P80318 差分可變間距TDR探頭提供了杰出的性能和*性測試功能,保證簡便準(zhǔn)確地測量背板和封裝器件。 在用戶結(jié)合使用這些模塊及泰克IConnect® TDR和VNA軟件時(shí),可以采集高達(dá)1,000,000的數(shù)據(jù)點(diǎn),獲得高達(dá)50 GHz的差分、混合模式和單端S參數(shù)測量結(jié)果。IConnect還可以進(jìn)行各種串行數(shù)據(jù)標(biāo)準(zhǔn)要求的阻抗、S參數(shù)和眼圖*性測試,及為千兆位互連進(jìn)行全通道分析、Touchstone (SnP)文件輸出和SPICE建模。 取樣模塊s: 80E09, 80E07, 80E06, 80E03, 80E02 和80E01 80E09和80E07是帶有遠(yuǎn)程取樣器的雙通道模塊,在60 GHz 取樣帶寬時(shí)實(shí)現(xiàn)了450 μVRMS的噪聲,在30 GHz 取樣帶寬時(shí)實(shí)現(xiàn)了300 μV的噪聲。每個(gè)小型遠(yuǎn)程取樣器連接到2米電纜上,使電纜、探頭和夾具的影響達(dá)到zui小,拉近了取樣器和DUT的距離,保證*的信號(hào)保真度。用戶可以選擇帶寬設(shè)置(80E09上為60/40/30,80E07上為30/20),實(shí)現(xiàn)了噪聲和帶寬的*平衡。 80E06和80E01是單通道70+和50 GHz帶寬的取樣模塊。80E06提供了zui寬的測量帶寬和zui快的上升時(shí)間測量功能及世界*的信號(hào)保真度。80E06和80E01都提供了杰出的±1.6 V的zui大工作范圍。這兩個(gè)模塊都可以與選裝的2米擴(kuò)展器電纜一起使用,保證杰出的信號(hào)保真度和測量靈活性。 80E03和80E02是雙通道20 GHz和12.5 GHz 取樣模塊。這些取樣模塊在80E03中提供了17.5 ps或更低的采集上升時(shí)間,在80E02中提供了28 ps的采集上升時(shí)間。這些模塊可以選裝2米擴(kuò)展器電纜。 在與泰克80SJNB抖動(dòng)、噪聲和BER軟件一起使用時(shí),這些模塊可以把抖動(dòng)和噪聲分隔為不同的成分,了解眼圖閉合的精確成因,準(zhǔn)確地推斷BER和三維眼圖輪廓。在與82A04相位參考模塊一起使用時(shí),可以把時(shí)基準(zhǔn)確性改善到低達(dá)200 fsRMS的抖動(dòng),再加上300 μV的本底噪聲和14位的分辨率,保證了測得信號(hào)zui高的信號(hào)保真度。 Characteristics | Application Type | Channels | Input Impedance | Channel Input Connector | Bandwidth*2 | 80E10 | True differential TDR, S-parameters and fault isolation | 2 | 50 ±1.0 Ω | 1.85 mm female, precision adapter to 2.92 mm included with 50 Ω SMA termination | 50/40/30 GHz*3,*4 | 80E09 | High frequency, low noise signal acquisition and jitter characterization | 2 | 50 ±1.0 Ω | 1.85 mm female, precision adapter to 2.92 mm included with 50 Ω SMA termination | 60/40/30 GHz*3,*4 | 80E08 | True differential TDR and S-parameters | 2 | 50 ±1.0 Ω | 2.92 mm female | 30/20 GHz*3,*4 | 80E07 | Optimal noise/performance trade off for jitter characterization | 2 | 50 ±1.0 Ω | 2.92 mm female | 30/20 GHz*3,*4 | 80E06 | High-speed electrical device characterization | 1 | 50 ±0.5 Ω | 1.85 mm female, precision adapter to 2.92 mm included with 50 Ω SMA termination | 70+ GHz | 80E04 | TDR impedance and crosstalk characterization | 2 | 50 ±0.5 Ω | 3.5 mm female | 20 GHz*3 | 80E03 | Device characterization | 2 | 50 ±0.5 Ω | 3.5 mm female | 20 GHz*3 | 80E01 | High frequency, high maximum operating range signal acquisition | 1 | 50 ±0.5 Ω | 2.4 mm female, precision adapter to 2.92 mm included with 50 Ω SMA termination | 50 GHz | *2 Values shown are warranted unless printed in an italic typeface which represents a non-warranted characteristic value that the instrument will typically perform to *3 Calculated from 0.35 bandwidth rise time product *4 User-selectable | Rise Time (10% to 90%) | DynamicRange | OffsetRange | Maximum Operating Voltage | Maximum Non-Destruct Voltage, DC+ACP-P | Vertical Number of Digitized Bits | 80E10 | 7 ps*5 | 1.0 Vp-p | ±1.1 V | ±1.1 V | 2.0 V | 14 bits full scale | 80E09 | 5.8 ps*5 | 1.0 Vp-p | ±1.1 V | ±1.1 V | 2.0 V | 14 bits full scale | 80E08 | 11.7*5 | 1.0 Vp-p | ±1.1 V | ±1.1 V | 2.0 V | 14 bits full scale | 80E07 | 11.7*5 | 1.0 Vp-p | ±1.1 V | ±1.1 V | 2.0 V | 14 bits full scale | 80E06 | 5.0 ps*5 | 1.0 Vp-p | ±1.6 V | ±1.6 V | 2.0 V | 14 bits full scale | 80E04 | ≤17.5 ps | 1.0 Vp-p | ±1.6 V | ±1.6 V | 3.0 V | 14 bits full scale | 80E03 | ≤17.5 ps | 1.0 Vp-p | ±1.6 V | ±1.6 V | 3.0 V | 14 bits full scale | 80E01 | 7 ps *5 | 1.0 Vp-p | ±1.6 V | ±1.6 V | 2.0 V | 14 bits full scale | *5 Calculated from 0.35 bandwidth rise time product | VerticalSensitivity Range | DC Vertical Voltage Accuracy, single point, within ±2 °C of compensated temperature | Typical Step Response Aberrations*6 | RMS Noise*6 | 80E10 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±1% or less over the zone 10 ns to 20 ps before step transition; +6%, –10% or less for the first 400 ps following step transition; +0%, –4% or less over the zone 400 ps to 3 ns following step transition; +1%, –2% or less over the zone 3 ns to 100 ns following step transition; ±1% after 100 ns following step transition | 50 GHz: 600 μV, ≤700 μV 40 GHz: 370 μV, ≤480 μV 30 GHz: 300 μV, ≤410 μV | 80E09 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±1% or less over the zone 10 ns to 20 ps before step transition; +6%, –10% or less for the first 400 ps following step transition; +0%, –4% or less over the zone 400 ps to 3 ns following step transition; +1%, –2% or less over the zone 3 ns to 100 ns following step transition; ±1% after 100 ns following step transition | 60 GHz: 450 μV, ≤600 μV 40 GHz: 330 μV, ≤480 μV 30 GHz: 300 μV, ≤410 μV | 80E08 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±1% or less over the zone 10 ns to 20 ps before step transition; +6%, –10% or less for the first 400 ps following step transition; +0%, –4% or less over the zone 400 ps to 3 ns following step transition; +1%, –2% or less over the zone 3 ns to 100 ns following step transition; ±1% after 100 ns following step transition | 30 GHz: 300 μV, ≤410 μV 20 GHz: 280 μV, ≤380 μV | 80E07 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±1% or less over the zone 10 ns to 20 ps before step transition; +6%, –10% or less for the first 400 ps following step transition; +0%, –4% or less over the zone 400 ps to 3 ns following step transition; +1%, –2% or less over the zone 3 ns to 100 ns following step transition; ±1% after 100 ns following step transition | 30 GHz: 300 μV, ≤410 μV 20 GHz: 280 μV, ≤380 μV | 80E06 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±5% or less for first 300 ps following step transition | 1.8 mV, ≤2.4 mV (maximum) | 80E04 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±3% or less over the zone 10 ns to 20 ps before step transition; +10%, –5% or less for the first 300 ps following step transition; ±3% or less over the zone 300 ps to 5 ns following step transition; ±1% or less over the zone 5 ns to 100 ns following step transition; 0.5% after 100 ns following step transition | 600 µV,≤1.2 mV (maximum) | 80E03 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±3% or less over the zone 10 ns to 20 ps before step transition; +10%, –5% or less for the first 300 ps following step transition; ±3% or less over the zone 300 ps to 5 ns following step transition; ±1% or less over the zone 5 ns to 100 ns following step transition; ±0.5% after 100 ns following step transition | 600 μV,≤1.2 mV (maximum) | 80E01 | 10 mV to 1.0 V full scale | ± [2 mV + 0.007 (Offset) + 0.02 (Vertical Value - Offset)] | ±3% or less over the zone 10 ns to 20 ps before step transition; +12%, –5% or less for the first 300 ps following step transition; +5.5%, –3% or less over the zone 300 ps to 3 ns following step transition; ±1% or less over the zone 3 ns to 100 ns following step transition; ±0.5% after 100 ns following step transition | 1.8 mV,≤2.3 mV (maximum) | *6 Values shown are warranted unless printed in an italic typeface which represents a non-warranted characteristic value that the instrument will typically perform to TDR System (80E10, 80E08, 80E04 only) | 80E10 | 80E08 | 80E04 | Channels | 2 | 2 | 2 | Input Impedance | 50 Ω nominal | 50 Ω nominal | 50 Ω nominal | Channel Input Connector | 1.85 mm | 2.92 mm | 3.5 mm | Bandwidth | 50 GHz | 30 GHz | 20 GHz | TDR Step Amplitude | 250 mV (polarity of either step may be inverted) | 250 mV (polarity of either step may be inverted) | 250 mV (polarity of either step may be inverted) | TDR System Reflected Rise Time | 15 ps | 20 ps | 28 ps | TDR System Incident Rise Time | 12 ps | 18 ps | 23 ps | TDR Step Deskew Range | ±250 ps | ±250 ps | ±50 ps | TDR Sampler Deskew Range | ±250 ps | ±250 ps | +100 ns -500 ps (slot deskew only) | TDR Step Maximum Repetition Rate | 200 kHz | 200 kHz | 200 kHz | Physical Characteristics | Dimensions (mm/in.) | Weight (kg/lbs.) | | Width | Height | Depth | Net | 80E10*7 | 55/2.2 | 25/1.0 | 75/3.0 | 0.175/0.37 | 80E09*7 | 55/2.2 | 25/1.0 | 75/3.0 | 0.175/0.37 | 80E08*7 | 55/2.2 | 25/1.0 | 75/3.0 | 0.175/0.37 | 80E07*7 | 55/2.2 | 25/1.0 | 75/3.0 | 0.175/0.37 | 80E06 | 79/3.1 | 25/1.0 | 135/5.3 | 0.4/0.87 | 80E04 | 79/3.1 | 25/1.0 | 135/5.3 | 0.4/0.87 | 80E03 | 79/3.1 | 25/1.0 | 135/5.3 | 0.4/0.87 | 80E01 | 79/3.1 | 25/1.0 | 135/5.3 | 0.4/0.87 | *7 Remote sampler module characteristics Ordering Information 80E10 Dual Channel, 50 GHz True Differential TDR Sampling Module with Remote Samplers Includes: User manual, certificate of traceable calibration standard, two precision adapters to 2.92 mm included with 50 Ω SMA terminations. 80E09 Dual Channel, 60 GHz Sampling Module. Includes: User manual, certificate of traceable calibration standard, two precision adapters to 2.92 mm included with 50 Ω SMA terminations. 80E08 Dual Channel, 30 GHz True Differential TDR Sampling Module with Remote Samplers Includes: User manual, certificate of traceable calibration standard, two 50 Ω SMA terminations. 80E07 Dual Channel, 30 GHz Sampling Module. Includes: User manual, certificate of traceable calibration standard, two 50 Ω SMA terminations. 80E06 70+ GHz Electrical Sampling Module. Includes: User manual, calibration data report, precision adapter to 2.92 mm with 50 Ω SMA termination. 80E06X2 - Bundled ordering configuration provides two 80E06 modules. 80E04 Dual Channel, 20 GHz True Differential TDR Sampling Module. Includes: User manual, calibration data report, two 50 Ω SMA terminations. 80E03 Dual Channel, 20 GHz Sampling Module. Includes: User manual, calibration data report, two 50 Ω SMA terminations. 80E01 Single Channel, 50 GHz Sampling Module. Includes: User manual, calibration data report, precision adapter to 2.92 mm included with 50 Ω SMA termination. Service Options Opt. C3 - Three years of Calibration Service. Opt. C5 - Five years of Calibration Service. Opt. D1 - Calibration data reports (not available with 80E07 – 80E10) Opt. D3 - Three years of Calibration data reports. Opt. D5 - Five years of Calibration data reports. Opt. R3 - Extended repair warranty to three years. Opt. R5 - Extended repair warranty to five years. Other Accessories Sampling Module Extender Cable (2 meter length) - Order 80N01 (not for use with 80E07 – 80E10) 2X Attenuator (SMA male-to-female) - Order 015-1001-01. 5X Attenuator (SMA male-to-female) - Order 015-1002-01. Adapter (2.4 mm male to 2.92 mm female – can also be used as 1.85 mm male to 2.92 mm female) - Order 011-0157-00. P8018 - 20 GHz Single-ended TDR Probe. 80A02 module (below) recommended for static protection of the sampling or TDR module. P80318 - 18 GHz Differential TDR Probe. 80A02 module (below) recommended for static protection of each channel of the sampling or TDR module. 80A02 - EOS/ESD Protection Module (1 channel). P8018 or P80318 TDR probe (above) recommended. Interconnect Cables (3rd party) Tektronix recommends using quality high performance interconnect cables with these high bandwidth products in order to minimize measurement degradation and variations. The W.L. Gore & Associates' cable assemblies, accessible at , are compatible with the 2.92 mm, 2.4 mm, and 1.85 mm connector interface of the 80Exx modules. Assemblies can be ordered by contacting Gore (at the URL above). Calibration Kits and Accessories (3rd party) To facilitate S-parameter measurements with these electrical modules and IConnect® software, we recommend precision calibration kits, adapter kits, connector savers, airlines, torque wrenches, and connector gauges from Maury Microwave. These components, accessible at are compatible with the 2.92 mm, 2.4 mm, and 1.85 mm connector interface of the 80Exx modules. Cal kits and other components can be ordered by contacting Maury Microwave (at the URL above). |