化工儀器網(wǎng)>產品展廳>半導體行業(yè)專用儀器>組裝與封裝設備>芯片開封機>JetetchPro-Cu Nisene化學芯片開封機CuProtect

JetetchPro-Cu Nisene化學芯片開封機CuProtect

具體成交價以合同協(xié)議為準

聯(lián)系方式:楊經(jīng)理查看聯(lián)系方式

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!


似空科學儀器(上海)有限公司是一家儀器設備的經(jīng)銷商。我們致力于為中國制造業(yè)和研發(fā)機構提供高精度、符合人體工學設計的儀器設備。我們也夢想有朝一日,能夠充分掌握市場需求,深刻理解儀器設備的技術原理,聚集一批有激情、有理想、有技術的人,為中國的制造業(yè)升級以及中國科研走向世界,提供自有知識產權的先進儀器設備!
儀器設備發(fā)展的是探測手段和傳感器不對被測目標產生任何干擾,企業(yè)管理的是一切以市場為核心,不以自我的意愿抗拒市場的趨勢,代替客戶的喜好,于是我們取名“似空”,希望以忘我的精神服務客戶。

 

失效分析,芯片開封,表面觀測,金相研磨,光學及視頻顯微鏡,超聲波檢測,X射線檢測,激光微納加工等

價格區(qū)間 面議 儀器種類 微流控芯片系統(tǒng)
應用領域 電子 具有銅線防護的化學芯片開封系統(tǒng) JetEtch Pro CuProtect

CuProtect工藝 - 美國專li8,945,343 B2-用施加的電壓解封裝。 

     具有銅線防護的化學芯片開封系統(tǒng) ---- JetEtch Pro CuProtect

     Protecting Those Sensitive Copper Wires.

      It just got easier.

        With the price of gold at an all-time high, a current trend in the manufacturing of integrated circuits is the shift from gold to copper bond wires. With this shift, the failure analyst of these processors is now challenged to successfully attain package decapsulation by use of traditional methods.

主要特征(Features):

    Patented Bias Technology 

    Advanced Software 

    Affordable 

    All JetEtch Pro Features 
 

The Old Methods.

        Historically, one would use an automated chemical decapsulation system to etch samples with copper wires — with minimal success. Even with a low-temperature nitric and sulfuric acid mixture, and even in combination with laser pre-opening, this process works to an extent, but is largely unreliable. When faced with a limited number of field failures, which is a common scenario in a failure analysis laboratory setting, less reliable processes can’t be counted on to deliver satisfactory failure analysis and visual inspection results.

The Solution.

        To support manufacturers in making this shift so that failure analysis can still be performed on their most advanced and cutting edge products which now use copper wire bonding, Nisene Technology Group has developed a version of its new JetEtch Pro decapsulation system that is specifically designed to handle the processing of this sensitive material: the JetEtch Pro CuProtect — the latest in a series of innovative solutions for the failure analysis industry from Nisene.

The Process.

CuProtect Principle Illustration        Using a proprietary and patented process, the JetEtch Pro CuProtect applies a bias to the solution being pumped to the sample in the process chamber. This bias creates a condition in which negatively-charged sulfate ions are attracted and temporarily bond to the surface of the copper wire while the sample is being etched. This temporary sulfate ion coating protects the copper wires from corrosion while the sample undergoes the etching process.

        The image to the right illustrates the operating principal behind the technique. Click on the image to open a larger version in a new window.

        In less sophisticated systems relying solely on low temperature etching, positively-charged hydrogen ions are attracted to the copper wires, thereby making the wires susceptible to pitting, cracking, breaking, and many other undesirable anomalous artifacts that greatly affect or even squelch completely the ability to perform failure analysis after the etching process. The Nisene Technology Group CuProtect system solves this problem.

The Results.

        As illustrated in the images below, the advanced bias application process yields results that are unmatched in the industry.

Protected Copper Wires Protected Copper Wires Protected Copper Wires 

        If you would like to see more examples of samples etched with the CuProtect, please contact us.
 

The Software.

        “Surely something like this must be complicated to use and difficult to understand — right?” you ask. The answer to that is “of course not!” The system appears on the outside to be the same as the JetEtch Pro, but there is an added line in its decapsulation programming menu that allows the user to change the value of the applied bias. The range is 0 V (off or no bias) to 20.0 V, selectable in .1 V increments. The other differences between the CuProtect system and the JetEtch Pro — both in hardware and software — are hidden inside the system, so operating the CuProtect is exactly like JetEtch Pro and virtually transparent to a user. That is to say: learning curve is very small. There’s no need to learn anything new other than how much voltage to apply to your sample while it is etching.

JetEtch Operation Screen JetEtch Pro CuProtect Operation Screen

        One additional parameter line. Not much to learn here!

 