化工儀器網(wǎng)>產(chǎn)品展廳>生命科學(xué)儀器>組織學(xué)設(shè)備>其它組織學(xué)設(shè)備>Vascular Simulation Vascular Simulations - Cardiac Cycl...
Vascular Simulation Vascular Simulations - Cardiac Cycle and Blood Flo
- 公司名稱 世聯(lián)博研(北京)科技有限公司
- 品牌
- 型號(hào) Vascular Simulation
- 產(chǎn)地
- 廠商性質(zhì) 代理商
- 更新時(shí)間 2017/7/5 14:18:54
- 訪問次數(shù) 980
Vascular Simulations Replicator血管模擬復(fù)制儀系統(tǒng)裝置動(dòng)力型帶瓣血復(fù)制器血管造影術(shù)血管模擬復(fù)制器Cerebrovascular Flow Loop
聯(lián)系方式:李勝亮18618101725 查看聯(lián)系方式
聯(lián)系我們時(shí)請(qǐng)說明是化工儀器網(wǎng)上看到的信息,謝謝!
細(xì)胞應(yīng)力加載儀,3細(xì)胞打印機(jī),NanoTweezer新型激光光鑷系統(tǒng),PicoTwist磁鑷,美國(guó)NeuroIndx品牌Kuiqpick單細(xì)胞捕獲切割系統(tǒng)
The Vascular Simulations Replicator (patent #9,183,763 B2) duplicates the cardiac cycle with a functional left atrium and ventricle with mechanical mitral and aortic valves. The “blood flow” then passes through a silicone aorta with a compliance that recreates the clinical Windkessel effect resulting in pressure waveforms in the aorta of the replicator that are indistinguishable from the waveforms of a human aorta. The great vessels arising from the aortic arch and the cerebrovasculature can be prototyped from imaging studies of actual patients and their entire vascular anatomy and pathology can be recreated with silicone. Currently, any intracranial aneurysm can be recreated. Additional modules under development include intracranial occlusion to mimic acute stroke, carotid stenosis, intracranial arteriovenous malformations, abdominal aortic aneurysms and aortic and mitral stenosis.
A proprietary clear blood analog with a viscosity matching that of human blood duplicates the friction coefficients of endovascular devices, wires, and catheters as they traverse the vascular system.The blood analog fluid is automatically warmed up to body temperature(98.6 °F) by the Replicator. In addition, the cerebrovasculature is housed in a polyurethane “head” filled with a gel that mimics the compliance of the brain parenchyma. As a result, the passage of wires and catheters into the cerebrovasculature mimics the straightening of vessels as visualized clinically.The Replicator comes with a Windows laptop with a pre-installed software application that operates the Replicator via Bluetooth connectivity. Software functions include filling, running, and draining the Replicator, as well as controls to change the heart rate and mean blood flow rates to the Head and Body. The plots below show the flow waveforms recorded on the Replicator at different arterial sites.
The whole system can be placed in any fluoroscopic environment and imaging can be performed in any machine including biplane angiography systems. Standard fluoroscopy, roadmap imaging, digital subtraction angiography and rotational angiography can be performed with any contrast agent and acquisition sequences identical to real clinical cases can be obtained. “Artificial kidney” systems to remove contrast from the circulatory system are under development.
Identical Anatomy and Pathology
Unlike virtual simulators which are essentially glorified video games, the Vascular Simulations Replicator provides a realistic experience when performing endovascular procedures. The user interface is the angiographic environment in combination with any endovascular access product or device utilized to perform an actual clinical case. In addition, custom silicone vessels that duplicate the actual anatomy and pathology can be manufactured. For the first time, interventionalists will be able to practice a procedure with the identical vascular pathology they will ultimay treat clinically.
Vessels Catalog
Consumables ↓
Vascular Simulations can create custom silicone vessels from the AXIAL SLICES reconstructed from a 3D rotational angiogram, CT angiogram, or MR angiogram of any patient's vasculature. Please select any of the ‘off-the-shelf’ vessels shown below or Upload your patient dataset and let us know. You can also send us your CAD or STL files instead of imaging datasets. Please note that the vessels are filled with red colored fluid for visualization. Any vessel in the catalog can be mirrored.
Narrow Search
- Intracranial Aneurysm
- Carotid Right
- Cavernous
- Ophthalmic
- Terminus
- MCA
- PCom
- ACom
- SCA
- Carotid Left
- Cavernous
- Ophthalmic
- Terminus
- MCA
- PCom
- ACom
- SCA
- Posterior
- Terminus
- Basilar
- Multi Aneurysm
- Aneurysm Neck
- 1.5-3.8 mm
- 3.81-4.74 mm
- 4.75- 5.55 mm
- 5.56-7.0 mm
- 7.01-16.60 mm
- Aneurysm Height
- 1.5- 4.70 mm
- 4.71-5.90 mm
- 5.91-7.2 mm
- 7.21-10.75 mm
- 10.76- 30.25 mm
- Aneurysm Width
- 1.5- 4.75 mm
- 4.76- 5.70 mm
- 5.71- 6.70 mm
- 6.71- 9.50 mm
- 9.51- 34.65 mm
- Aneurysm Depth
- 1.5- 4.85 mm
- 4.86- 6.10 mm
- 6.11- 7.50 mm
- 7.51-10.10 mm
- 10.11- 28.75 mm
Model # 001
N 5.50 H 21.00 W 24.60 D 24.80Model # 002
N 4.20 H 20.30 W 9.20 D 9.90Model # 003
N 7.80 H 20.20 W 30.70 D 20.80Model # 004
N 7.70 H 12.30 W 9.30 D 11.70Model # 005
N 6.90 H 8.40 W 5.90 D 6.50Model # 007
N 5.30 H 6.70 W 6.20 D 5.50Model # 008
N 4.90 H 8.80 W 6.40 D 8.00Model # 011
N 8.70 H 13.20 W 13.80 D 15.00Model # 012
N 4.50 H 5.20 W 4.70 D 5.60Model # 013
N 6.40 H 6.30 W 5.20 D 5.90Model # 015
N 3.70 H 6.30 W 5.60 D 8.40Model # 016
N 5.80 H 14.40 W 11.70 D 13.90