LSS-15AX-C3A 雷電浪涌模擬器
- 公司名稱 深圳市華瑞高電子技術有限公司
- 品牌
- 型號 LSS-15AX-C3A
- 產地
- 廠商性質 代理商
- 更新時間 2018/1/30 21:52:15
- 訪問次數(shù) 728
聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!
靜電放電發(fā)生器,靜電放電模擬器,靜電槍,電快速脈沖發(fā)生器,雷擊浪涌發(fā)生器,周波跌落發(fā)生器,工頻磁場發(fā)生器,電壓跌落發(fā)生器,衰減振蕩波發(fā)生器
雷電浪涌模擬器LSS-15AX-C3A FEATURES :
雷電浪涌模擬器LSS-15AX-C3AFully compliant with the requirements called for in the 2nd edition of IEC 61000-4-5 standard, the LSS-15AX series simulators provide a testing facility for up to 15kV test voltage without sacrificing safety and ease of use. The LSS-15AX simulators generate the two combination pulses 1.2/50 µs (8/20 µS) and 10/700 µS (5/320 µS).
公司名稱:深圳市華睿高電子技術有限公司/肖
: :
LSS-15AX-C3A FUNCTIONS
| Very intuitive settings can be done by the assistance of the well configured user-interface consisting of a 5-inch LCD, ten-key, functions keys and others. Coupling modes are graphically shown, allowing the operator to select the desired mode and allows easy reference of settings when the test is in progress. |
| This button, easily accessible and placed on the front panel, enables the operator to stop the generation of the pulses anytime he/she desires. In addition to the high voltage power, the operator can turn off the EUT. |
| A safely interlock is provided through the special design high voltage connector. The high voltage circuitry never be activated when the connector is not correctly positioned or not firmly locked. |
| The value of the actual peak amplitude is measured and shown for both voltage and current. |
| LSS-15AX-C3A stops generating the pulses if the peak current measured exceeds the threshold limit which can be freely set as the breakdown criteria. |
LSS-15AX-C3A SPECIFICATIONS |
|
LSS-15AX-C3A DISPLAY EXAMPLES |
LSS-15AX-C3A menus can be selected in the menu display.
| ||
MANUAL MODE TEST SETTING DISPLAY (1) When manual mode test is selected in the menu display, the corresponding test setting display will be shown. The output voltage, waveform and other test parameters can be set. Unnecessary items are indicated lightly and the simulator does not accept change in setting. | ||
MANUAL MODE TEST SETTING DISPLAY (2) Some items can be selected on pop up menus. The right example shows the choices on "Output To". | ||
AC/DC INJECTION SETTING DISPLAY Press the coupling mode key. Coupling mode selection screen will appear. The example shows the 3-phase AC CDN screen on which coupling and return lines can be set. On the ecom CDN setting screen the number of lines (2 or 4 lines), limit resistance (25 ohm or 40 ohm) and return line (1, 2, 3, 4 or PE) can be set. |
LSS-15AX-C3ATEST SET UP EXAMPLE LSS-15AX-C3A Capacitive coupling on single-phase AC lines in Line-to-line & line-to-ground mode |
INCLUDED ACCESSORIES |
LSS-15AX-C3AThe following accessories are included.
- AC line input cable (4-core: 2m): 1pc
- DC line input cable (3-core: 2m): 1pc
- Surge output cable for surge output (2m) : 2 pcs
- Surge output cable for injection line (2m) : 5 pcs
- Monitoring coaxial cable (1m): 2 pcs
- PE cable (for main unit: 2m): 1pc
- PE cable (for injection line: 2m): 1pc
- Interlock connector: 1pc
- Instruction manual: 1 pc (English)
- Connector caps (7pcs) are fitted to the main unit when it leaves our factory.